期刊文献+

电站锅炉引风机系统节能分析 被引量:2

Energy analysis of power station boiler fan system
下载PDF
导出
摘要 针对循环流化床机组引风机运行过程中能耗大的问题,结合型号为Y4-2×60-14NO.33F的引风机具体运行参数,根据风机性能曲线、变工况管路特性曲线及风机调节方式,分析了风机选型偏大、管路特性曲线变化及风机变工况调节等因素下对风机效率的影响。通过引风机系统节能的分析,为引风机的选型及节能改造提供理论依据。 Aimed to the problem of induced draft fan for circulating fluidized bed during the operation of large energy consumption,combined with model Y4-2 60-14 NO. 33 F specific operating parameters of the induced draft fan,according to the fan performance curve,variable condition pipeline characteristic curve and fan adjustment manner,under the influence of fan selection is too large,the pipeline characteristic curve and the fan variable conditions regulator and other factors on the efficiency of the fan. By analyzing the induced draft fan system energy saving,it Provides a theoretical basis for the selection and energy saving for induced draft fan.
作者 景博 张培华
出处 《节能》 2016年第7期31-36,2,共6页 Energy Conservation
基金 山西省煤基重点科技攻关项目(项目编号:MD2014-03)
关键词 引风机 节能 管路特性曲线 风机选型 变速调节 induced draft fan energy-saving pipeline characteristic curve fan selection variable-speed control
  • 相关文献

参考文献5

二级参考文献3

  • 1上海经委节能办公室 等.风机水泵调速节能手册[M].机械工业出版社,1987.18.
  • 2上海经委节能办公室,风机水泵调速节能手册,1987年,18页
  • 3周谟仁,流体力学.泵与风机,1985年

共引文献65

同被引文献5

引证文献2

二级引证文献3