摘要
对该核电站常规岛地下空间的结露情况进行了分析和调研,提出了通过合理调节和控制厂房温度,确保厂房内有结露风险的实体表面温度高于室外空气露点温度,从而避免厂房内产生结露现象的措施。针对该核电站常规岛,给出了地下空间合理的设计温度。
Analyses and surveys the condensation conditions in the underground space of turbine building of this nuclear power plant.Proposes the anti-condensation measures by properly regulating and controlling the temperature of the plant to keep surface temperature of indoor objects above the dew point temperature of outdoor air.According to the turbine building of the nuclear power plant,gives out the reasonable design temperature in underground space.
出处
《暖通空调》
北大核心
2016年第8期98-102,共5页
Heating Ventilating & Air Conditioning
关键词
核电厂
常规岛
地下空间
结露
通风系统
nuclear power plant
turbine building
underground space
condensation
ventilation system