期刊文献+

预应力方套管连接胶合木梁柱节点抗弯试验 被引量:6

Rotational Performance of Pre-Stressed MultiBolted Glulam Connection with Square Tubes
下载PDF
导出
摘要 提出在胶合木结构中采用预应力方套管螺栓连接,该连接采用高强螺栓和钢套管作为连接件.通过单调加载和往复加载下的梁柱节点抗弯试验,对比了方套管节点和传统螺栓群连接节点的破坏模式、弯矩-转角曲线、滞回曲线、强度、刚度和耗能性能.结果表明,由于摩擦阶段钢管与钢板间的摩擦力确保了初始传力,套管节点的初始转动刚度显著提升,耗能能力也得到改善. This paper presents an experimental study on the moment resisting capacity and stiffness of the proposed pre- stressed bolted connection. High-strength bolts with square tubes were used as fasteners in such connections. Two groups of experimental tests were conducted with T-shaped glulam beam-to-column connections at monotonic and reversed cyclic loading. The failure mode, moment-rotation curve, strength, stiffness and energy dissipation property of the pre-stressed bolted connections with square tubes were obtained and compared with those of traditional bolted connections. The results show that the initial rotational stiffness of pre-stressed bolted connection increases significantly as a result of the friction between steel tubes and steel plate at the friction stage, and the energy dissipation capacity of pre-stressed bolted connection is also improved.
出处 《同济大学学报(自然科学版)》 EI CAS CSCD 北大核心 2016年第8期1182-1189,共8页 Journal of Tongji University:Natural Science
基金 国家自然科学基金(51378382)
关键词 胶合木结构 方套管螺栓连接 预应力 摩擦 刚度 glulam structure multi-bolted connection with square tubes prestress fraction rotational stiffness
  • 相关文献

参考文献17

  • 1Lain F, Gehloff M, Closen M. Moment-resisting bolted timber connections[J]. Structures and Buildings, 2010, 163 (4) : 267.
  • 2Redd P D, Leijten A J M. High-performance dowel-type joints for timber structures[J]. Timber Construction, 2003, 5 (2) : 77.
  • 3Leijten A J M. Development of reinforced joints with densified veneer wood[C/CD]// Proceedings of the 1991 International Timber Engineering Conference. London: [ s. n. ], 1991 : 3.36.
  • 4Haller P, Birk T, Offermann P, et al. Fully fashioned biaxial weft knitted and stitch bonded textile reinforcements for woodconnections[J]. Composites~ Part B, 2006, 37(4/5):278.
  • 5Blass H J, Schmid M, Litze H, et al. Nail plate reinforced joints with dowel-type fasteners[C/CD]// Proceedings of the World Conference on Timber Engineering. Whistler: [s. n. ], 2000: 8.6.4.
  • 6Blass H J, Schadle P. Ductility aspects of reinforced and non- reinforced timber joints [J]. Engineering Structures, 2011, 33: 3018.
  • 7Leijten A J M. Locally reinforced timber joints with expanded tube fasteners[J]. Heron, 1999, 44(3): 131.
  • 8Leijten A J M, Ruxton S, Prion H, et al. Reversed-cyclic behavior of a novel heavy timber tube connection[J]. Sructural Engineering, 2006, 132(8): 1314.
  • 9HE Minjuan, ZHAO Yi, MA Renle. Experimental investigation on lateral performance of pre-stressed tube bolted connection with high initial stiffness [J ]. Advaces in Structural Engineering, 2016, 19(5): 762.
  • 10中华人民共和国建设邵.6B50005--Z003木结构设计规范[S].北京:中国建筑工业出版社,2003.