期刊文献+

环境γ辐射剂量率仪现场校准用辐照装置的研制 被引量:9

Development of an irradiation device for on-site calibration of environmental gamma radiation dose rate meter
原文传递
导出
摘要 为开展环境γ辐射剂量仪的现场校准,研制了一套辐照装置,其辐射场空气比释动能率可在0.27-34.86μGy·h^(-1)范围内通过距离与减弱器来调节。基于大量Geant4蒙特卡罗模拟设计了一种轻便型辐射准直器,在保证辐射场品质的前提下,大大降低了准直器重量,更适用于现场校准。此外,还研制了一套自动化支撑平台与三片曲面辐射减弱器,可远程实现辐射装置空间定位以及辐射场强度和空间的调节,曲面辐射减弱器有利于保证辐射场均匀性。测试实验及蒙特卡罗模拟结果显示,该辐射装置辐射场再现性、自散射、均匀性等性能良好,通过系统地计算地面散射对辐射场的影响,可为现场校准提供指导。 Background: With the development of the nuclear safety technology in China, more and more environmental gamma radiation dose rate meters were fixed in the field to monitor the environmental radiation in real time. Calibration of these meters is inconvenient to do on-site. Purpose: This study aims to design and implement a portable irradiation device for on-site calibration of these dose rate meters. Methods: An irradiation collimator was designed through Monte Carlo simulation as the kernel component of the irradiation device, and an automated supporting platform with functionalities of ranging, shifting, switching attenuation plates and remote control of intensity and position was developed as the additional component. Experiments and Monte Carlo simulations were conducted to test the performance of the irradiation device and calibrate the air kerma rate in the radiation filed of it. Field-testing was also performed to check the practicability of this irradiation device on condition of on-site calibration. Results: The adjustable range of the air kerma rate in the reference radiation filed was 0.27-34.86 tGy.h-a. The self-developed irradiation device had good performance on reproducibility, self-scattering,homogeneity and practicability in field application. Conclusions: A portable irradiation device was designed and developed through Monte Carlo simulation for the calibration of on-site dose rate meter, it can be nsed to achieve the traceability of the fixed environmental gamma radiation dose rate meter.
出处 《核技术》 CAS CSCD 北大核心 2016年第9期7-12,共6页 Nuclear Techniques
基金 质检总局科技计划项目(No.2015QK046) 上海市质监局科研项目(No.2015-2X001)资助~~
关键词 现场校准 辐照装置 辐射准直器 散射 均匀性 On-site calibration, Irradiation device, Irradiation collimator, Scattering, Homogeneity
  • 相关文献

参考文献7

  • 1刘华,赵顺平,梁梅燕,邵海江,倪士英.我国辐射环境监测的回顾与展望[J].辐射防护,2008,28(6):362-376. 被引量:53
  • 2高飞,肖雪夫,倪宁.固定式环境γ辐射剂量率仪现场校准技术[J].原子能科学技术,2015,49(2):212-217. 被引量:17
  • 3国家质量技术监督总局.GB/T12162.1-2000:用于校准剂量仪和剂量率仪及确定其能量响应的x和v参考辐射(第一部分:辐射特性及产生方法)[S].北京:中国标准出版社,2001.
  • 4The State Administration of Quality and Technical Supervision. GB/T 12162.1-2000: X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: radiation characteristics and production methods[S]. Beijing: Standard Press of China, 2001.
  • 5Geant4 Collaboration. Geant4 user's guide for application developers[M]. CERN, 2015:1.
  • 6Geant4 Collaboration. Physics reference manual[M]. CERN, 2015:182.
  • 7National Institute of Standards and Technology. XCOM program[CP/OL]. 2016-5-18. http://physics.nist.gov/ PhysRe fData/Xcom/Text/chap4.html.

二级参考文献30

  • 1于水,王功鹏,关守任.低大气层宇宙射线剂量水平及机组人员受照剂量的研究[J].辐射防护,1997,17(2):103-108. 被引量:7
  • 2联合国原子辐射科学效应委员会(UNSCEAR).电离辐射源与效应.UNSCEAR1993年报告.北京:原子能出版社.1995
  • 3国家环境保护总局办公厅文件.关于印发《国家环保总局核事故应急预案》和《国家环保总局辐射事故应急预案》的通知.环办[2007]17号.2007-01
  • 4国家环境保护总局文件.关于印发《辐射环境监督站建设标准(试行)》的通知.环发[2002]158号.2002.11
  • 5中华人民共和国环境保护行业标准.辐射环境监测技术规范.HJ/T61.2001.2001-08
  • 6国家环境保护总局文件.关于印发《全国辐射环境监测与监察机构建设标准》的通知.环发[2007]82号.2007-06
  • 7国家环境保护总局办公厅文件.关于印发《全国辐射环境监测方案(暂行)的通知》.环办函[2003]56号.2003-06
  • 8国家环境保护总局辐射环境监测技术中心文件.《国家辐射环境监测网站站点布设原则与要求》(国环辐监[2006]21号).2006-10
  • 9国家环境保护总局办公厅文件.关于确定国家辐射环境监测网第一批国控点点位的通知.环办函[2007]168号.2007-03
  • 10国家环境保护总局辐射环境监测技术中心文件.关于报送国家辐射环境监测网第一批国控点建设和运行情况报告及核环境安全预警监测站点监测实施方案的通知.国环辐监[2007]12号.2007-04