摘要 为掌握严寒地区乡村民居的室内热环境变化规律及采暖特征,选择三栋典型乡村民居进行冬季室内热环境测试与分析及室内热舒适温度、采暖耗煤量调查。结果表明,由于严寒地区乡村民居平面布局不合理、围护结构热工性能差、采暖方式的局限性原因导致室内温度稳定性差、采暖能耗高等问题,居民对冬季室内热舒适性的满意度较低。 In order to grasp the change rule of indoor thermal environment and the heating characteristics, this paper selects three typical rural dwellings to test & analyze the indoor thermal environment in winter, meanwhile survey the indoor thermal comfort temperature and coal consumption of heating. The results shows that because of the unreasonable plane layout, poor thermal performance of envelope and the limitations of heating system, it caused a series of questions such as the indoor temperature is low and instability, coal consumption increased, therefore the residents have low satisfaction with the indoor thermal environment.
作者 邵腾 金虹
出处 《建筑技术》 北大核心 2016年第10期883-886,共4页 Architecture Technology
基金 国家自然科学基金(51378136)
关键词 严寒地区 传统民居 热环境 severe cold regions rural dwellings thermal environment
  • 相关文献

参考文献4

二级参考文献9

  • 1S·A·康兹 魏润柏.人与室内环境[M].北京:中国建筑工业出版社,1985.31-32.
  • 2金虹,哈尔滨建筑工程大学学报,2000年,4期,74页
  • 3JGJ 24-86 民用建筑热工设计规程
  • 4JGJ 26-95 民用建筑节能设计标准(采暖居住建筑部分)
  • 5B.吉沃尼.人·气候·建筑[M].陈士麟译,王建瑚校.北京:中国建筑工业出版社,1982.
  • 6L.巴赫基著,付忠诚等译.房间的热微气候[M].北京:中国建筑工业出版社.1987
  • 7MCINTYRE D A.Indoor Climate[M].London:Applied Science Published LTD,1980.
  • 8金虹,李连科,陈庆丰,沈红霞,陈新阳.北方村镇住宅外围护结构衰减度指标的研究与应用[J].哈尔滨建筑大学学报,2000,33(4):74-79. 被引量:14
  • 9金虹,赵华.关于严寒地区乡村住宅节能设计的思考[J].哈尔滨建筑大学学报,2001,34(3):96-100. 被引量:35

共引文献87

同被引文献74

引证文献10

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部