摘要
本文介绍了某县艺术中心的冷热源系统、空调通风系统、防火及排烟系统、消声及隔振系统的设计,对影剧院这类建筑在设计过程中的气流组织、防火排烟、消声隔振及运行管理等问题进行了总结。
The design of cold and heat source system, air conditioning and ventilation system, fire and smoke exhaust system, noise elimination and the isolation system of Art Center is introduced in this paper, and the problems of the design process of airflow organization, fire and smoke, noise vibration mode and operation management were analyzed.
出处
《建筑热能通风空调》
2016年第10期94-98,共5页
Building Energy & Environment
关键词
观众厅
舞台
性能化防火设计
消声减震
auditorium
stage
pcrformauce based fire protection design
shock absorption