期刊文献+

基于FPGA与DDS的磁共振成像射频脉冲发生器 被引量:4

A Radio Frequency Pulse Generator for Magnetic Resonance Imaging Based on FPGA and DDS
下载PDF
导出
摘要 设计了一种基于现场可编程门阵列(FPGA)与直接数字频率合成(DDS)的磁共振成像(MRI)射频脉冲发生器,采用FPGA实现DDS,并内置软脉冲波形双端口随机存取存储器(RAM)、乘法器以及相关的控制逻辑.实现了较高的技术指标,其中频率、相位与幅度分辨率分别为32 bits、16 bits与16 bits,软脉冲波形的时间精度可达0.1?s.FPGA提供了一个可编程的接口,便于序列控制器对其进行控制,以输出射频脉冲.MRI实验结果证明了该设计的可行性. A radio frequency (RF) pulse generator for magnetic resonance imaging (MRI) was designed based on field programmable gate array (FPGA) and direct digital synthesis (DDS). The generator utilizes FPGA to achieve DDS and embed soft pulse waveform (RAM), multiplier and related control logic. The RF generator showed high technical specifications, with frequency, phase and amplitude resolution up to 32 bits, 16 bits and 16 bits, respectively. Time precision of the soft pulse waveform reached 0.1 μs. FPGA provided a programmable interface, facilitating the control from sequence controller and generation of RF pulses. The feasibility of the design was demonstrated with imaging experiments.
作者 李聿为 肖亮 LI Yu-wei XIAO Liang(Department of Information Engineering, College of Information Science & Technology, Beijing University of Chemical Technology, Beijing 100029, China)
出处 《波谱学杂志》 CAS CSCD 北大核心 2016年第4期590-596,共7页 Chinese Journal of Magnetic Resonance
基金 国家自然科学基金资助项目(81227003)
关键词 磁共振成像(MRI) 射频脉冲发生器 现场可编程门阵列(FPGA) 直接数字频率合成(DDS) MRI, radio frequency pulse generator, field programmable gate array (FPGA), direct digital synthesis (DDS)
  • 相关文献

参考文献8

二级参考文献81

  • 1徐勤,沈杰,蒋瑜,李鲠颖.一体化核磁共振数字接收机的设计[J].波谱学杂志,2005,22(4):357-365. 被引量:12
  • 2宁瑞鹏,徐勤,沈杰,李鲠颖.基于PCI总线的全功能数字化频率源[J].波谱学杂志,2006,23(2):209-215. 被引量:7
  • 3刘颖,沈杰,李鲠颖.基于USB总线的一体化核磁共振谱仪控制台[J].波谱学杂志,2007,24(1):35-41. 被引量:7
  • 4Li Gengying,Xie Haibin.Digital quadrature detection in nuclear magnetic resonance spectroscopy[J].Rev Sci Instrum,1999,70(2):1 511-1 513.
  • 5Li Gengying,Jiang Yu,Yan Xiaolong,et al.Digital nuclear magnetic resonance spectrometer[J].Rev Scic Instrum,2001,72(12):4 460-4 463.
  • 6Jiang Yun,Jiang Yu,Tao Hongyan,et al.A complete digital radio-frequency source for nuclear magnetic resonance spectroscopy[J].Rev Sci Instrum,2002,73(9):3 329-3 331.
  • 7PCI 9052 Data Book,Version 2.0.PLX Technique Inc.2001-09.
  • 8AD9854 Data Book,Revision C.Anolog Device Inc.2004-10.
  • 9DRX programming user manual[Z].resonance instruments Ltd, 2002.
  • 10Michal Carl A, Broughton Kesten, Hansen Elsa. A high performance digital receiver for home-built nuclear magnetic resonance spectrometers [J]. Rev Sci Instrum, 2002, 73: 453-458.

共引文献35