根据传统挥发酚检测方法——4-氨基安替比林分光光度法的原理,开发出一种简便、实用的挥发酚在线蒸馏-检测系统。在蒸馏温度为130℃,进样量为2.00 mL/min条件下,吸光度与酚质量浓度的线性方程为A=0.004 5ρ+0.005 7,线性检测范围在1.00~180.00 mg/L,检出限为0.81 mg/L,相对标准偏差为3.5%(10.00 mg/L,n=8)和2.8%(35.00 mg/L,n=8),实际污水的加标回收率在99.8%~104.0%。同时将显色反应中带有刺激性气味的氨-氯化铵缓冲液替换为p H=10.5的氢氧化钠溶液,检测结果没有发生明显变化。
Based on the principle of color-reaction of phenol with 4-amino-antipyrine, a simple and practical measuring system for volatile phenols, named as on-line distillation-detection system, is developed. When the onlinedistillation temperature is 130 C and sample quantity is 2. 00 mL/min, the linear equation between absorbance and phenol content is A =0. 004 5p +0. 005 7 with the linear detection range of 1.00 - 180. 00 mg/L and detection limit of 0. 81 mg/L. The relative standard deviation is 3.5% for 10. 00 mg/L of volatile phenols ( n = 8 ) and 2. 8% for 35.00 mg/L of volatile phenols ( n = 8 ). The recoveries of standard additions for actual sewage are 99. 8% - 104. 0%. Meanwhile,the ammonia-ammonium chloride buffer with irritating odor in the chromogenic reaction is replaced with sodium hydroxide (pH = 10. 5 ) in this paper. Test results have not been obviously affected.