期刊文献+

计算机辅助设计与制造树脂暂时冠与自凝树脂、Luxatemp暂时冠的边缘密合度比较 被引量:9

Comparative evaluation of the marginal accuracy of single crowns fabricated computer using aided design/computer aided manufacturing methods, self-curing resin and Luxatemp
下载PDF
导出
摘要 目的比较自凝树脂、Luxatemp与计算机辅助设计与制造(CAD/CAM)树脂暂时冠修复体的边缘密合度差异。方法按全冠牙体制备标准预备牙体30个,取模并灌注石膏模型后,分别制作自凝树脂、Luxatemp与CAD/CAM树脂暂时冠各30个,将其就位于石膏模型上。通过体式显微镜,对利用硅橡胶复制技术得到的暂时冠与石膏模型间的边缘间隙宽度代型进行测量,计算各组30个样本边缘间隙的平均值。采用SPSS 19.0软件包对实验数据进行单因素方差分析。结果自凝树脂、Luxatemp与CAD/CAM树脂暂时冠边缘间隙平均值分别为(179.06±33.24)、(88.83±9.56)和(43.61±7.27)μm。CAD/CAM树脂暂时冠边缘间隙显著小于自凝树脂和Luxatemp暂时冠(P<0.05),自凝树脂暂时冠边缘间隙显著大于Luxatemp与CAD/CAM树脂暂时冠(P<0.05)。结论 CAD/CAM树脂暂时冠边缘密合度显著优于自凝树脂和Luxatemp暂时冠,CAD/CAM具有较高的临床应用价值。 Objective This study aims to compare the marginal accuracy of single crowns fabricated using self-curing resin, Luxatemp, and computer aided design/computer aided manufacturing (CAD/CAM) methods in clinical application. Methods A total of 30 working dies, which were obtained from 30 clinical teeth prepared with full crown as standard, were created and made into 30 self-curing resin, Luxatemp, and CAD/CAM single crowns. The restorations were seated on the working dies, and stereomicroscope was used to observe and measure the thickness of reference points. One-way analysis of variance, which was performed using SPSS 19.0 software package, compared the marginal gap widths of self-curing resin, Luxatemp, and CAD/CAM provisional crowns. Results The mean marginal gap widths of the fabricated self-curing resin, Luxatemp, and CAD/CAM were (179.06±33.24), (88.83±9.56), and (43.61±7.27) μm, respectively. A significant difference was observed among the three provisional crowns (P〈0.05). Conclusion The marginal gap width of CAD/CAM provisional crown was lower than that of the self-curing resin and Luxatemp. Thus, the CAD/CAM provisional crown offers a better remediation effect in clinical application.
出处 《华西口腔医学杂志》 CAS CSCD 北大核心 2016年第6期575-578,共4页 West China Journal of Stomatology
基金 上海市黄浦区卫生系统优秀青年人才培养项目(2014-20-16)~~
关键词 暂时性修复体 计算机辅助设计与制造 边缘密合度 provisional restoration computer aided design/computer aided manufacturing methods marginal adaptation
  • 相关文献

参考文献1

二级参考文献14

  • 1苏庭舒,孙健.口内数字化印模技术[J].中华临床医师杂志(电子版),2012,6(19):5780-5782. 被引量:26
  • 2陈悦,黎红,赵云凤,梁星.Cerec 2型机摄像头的口外控制装置对CAD/CAM全瓷底层冠适合性的影响[J].华西口腔医学杂志,2005,23(3):247-250. 被引量:11
  • 3Euan R, Figueras-Alvarez 0, Cabratosa- Tennes J, et al. Comparison of the marginal adaptation of zirconium dioxide crowns in preparations with two different finish lines[J]. J Prosthodont, 2012, 21(4):291-295.
  • 4Kohorst P, Brinkmarm H, Li J, et al. Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems[J]. Eur J Oral Sci, 2009,117(3):319-325.
  • 5Felton DA, Kanoy BE, Bayne SC, et al. Effect of in vivo crown margin discrepancies on periodontal health[J]. J Prosthet Dent, 1991,65(3):357-364.
  • 6American Dental Association. ANSI/ADA Specification No.8 for zinc phosphate cement. In: guide to dental materials and devices[M]. 5th ed. Chicago: American Dental Association, 1970.
  • 7McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique[J]. Br Dent J, 1971, 131(3):107-111.
  • 8Euan R, Figueras-Alvarez 0, Cabratosa-Termes J, et al. Marginal adaptation of zirconium dioxide copings: influence of the CAD/CAM system and the finish line design[J]. J Prosthet Dent, 2014,112(2):155-162.
  • 9Tsitrou EA, Northeast SE, van Noort R. Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAM[J]. J Dent, 2007, 35(1):68-73.
  • 10Gassino G, Barone Monfrin S, Scanu M, et al. Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure[J]. Int J Prosthodont, 2004, 17(2):218-223.

共引文献18

同被引文献68

引证文献9

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部