以某室内主题乐园为研究对象,针对建筑体量大、建筑空间跨度大、人员众多、内部游乐空间及游乐设施的设置相对复杂的室内主题乐园系统地进行消防安全专项论证。提出控制火灾荷载、强化防火分隔、增设避难走道、设置机械排烟及补风系统、设置自动跟踪定位射流灭火系统及自动喷淋灭火系统等优化措施。设计火灾场景和疏散场景,对室内主题乐园安全疏散和烟控策略等内容进行模拟计算。结果表明,现有的设计方案能够在火灾时保证人员的安全疏散。
According to the large space,long-span structures used in the indoor theme park,and also with high-density persons,complexities for amusement space and facilities emerge in the park,the fire safety strategies of the indoor theme park shall be analyzed,the Wanda Mao in Nanning witch is the indoor theme park is carried out as an example to illustrate the analysis in the paper.The optimization measures for evacuation,fire compartment and smoke control in the Wanda Mao are mainly proposed.Performance-based fire safety engineering is applied in the paper,and the fire simulation models are built to assess the fire safety strategies of the Wanda Mao,the simulation results of evacuation and smoke control in the Wanda Mao are presents.It concludes that the fire safety strategies of the Wanda Mao in Nanning are practicable,and the person in the Wanda Mao could evacuate safely.