期刊文献+

调节频率与风门测试风机性能的比较分析 被引量:3

Comparative Analysis on Performance Curves of Main Mine Fan Tested by Changing Converter and Adjusting Air Door
原文传递
导出
摘要 通过用变频器改变风机转速测定主通风机性能曲线和调节风门改变风机工况点测试主通风机性能曲线2种方法对比,以仁寿县天峨乡红光煤矿风机的测定为例。应用合理的测定及计算方法,进行相关参数的计算并绘制风机性能曲线图;通过对2种测定结果的对比分析得出能否利用改变风机频率来测定风机性能的结论。 As the frequent application of converter to the main fan in coal mining industry, new project and research direction are brought up for our inspection work. Takes it as an example the data tested in Hongguang mine of Tianer town, Renshou county. Through the comparison between the performance curve of main mine fan tested by using converter to change fan operating point,and applying to change the fan speed and that by adjusting air door proper testing and calculating method,comes to a conclusion that testing fan's performance curve by changing fan frequency is not workable.
作者 常杰
出处 《煤炭技术》 CAS 北大核心 2017年第2期259-260,共2页 Coal Technology
关键词 主通风机 性能曲线 变频风机 工况调节 main mine fan performance curve frequency conversion fan adjustment
  • 相关文献

参考文献3

二级参考文献19

  • 1李庆宜.通风机[M].西安:西安交通大学出版社,1996..
  • 2.MT421-1996.煤矿用主要通风机现场性能参数测定方法[S].,1996..
  • 3GB/T22670--2008,变频器供电三相笼型感应电动机试验方法[S].2008.
  • 4龚立娇,吴延祥,李玲.三相功率的测量方法[D].新疆:石河子大学,2005.
  • 5刘丽君,伍斌.三相电功率两表测量接线方法的研究[D].成都:西南师范大学,2002.
  • 6朱仕文.通风机性能现场测试技术讨论会在东工召开.东北大学学报:自然科学版,1984,(4).
  • 7程根银,漆旺生.芦岭煤矿西部风井通风系统改造效果分析[A].第十四届海峡两岸及香港、澳门地区职业安全健康学术研讨会暨中国职业安全健康协会2006年学术年会论文集[c],2006:484-487.
  • 8李庆宜.通风机[M].西安:西安交通大学出版社,1996..
  • 9MT421—1996.煤矿用主要通风机现场性能参数测定方法[S].[S].,..
  • 10张国枢.通风安全学[M].徐州:中国矿业大学出版社,2003.

共引文献18

同被引文献7

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部