期刊文献+

42CrMo钢法兰开裂分析 被引量:5

Fracture Failure Analysis of 42CrMo Steel Flange
下载PDF
导出
摘要 42CrMo钢法兰经860℃淬火和570℃回火后发现表面出现裂纹。通过化学成分分析、显微硬度测定、金相检验和冲击试验等方法分析了法兰开裂的原因。结果表明,裂纹的侧面存在氧化物,说明裂纹是在淬火过程中发生的。改进措施为:采用预冷淬火工艺,用聚合物溶液淬火代替水淬,或适当降低淬火加热温度。 Crack was found in 42CrMo steel flange which has been quenched from 860 ~C in water and tempered at 570 ~C. The flange having crack was subjected to composition analysis, microhardness measurements, metallographic examination, and impact tests to reveal the reason why the crack develop. The results indicate that oxides are present in the sides of crack, this shows the crack forms during the quenching of flange. The flange may be prevented from cracking by the use of delay quenching, quenching in polymer solution instead of water, or appropriate reduction in austenitizing temperature.
作者 贺凯林 金丽萍 HE Kailin JIN Liping(Jiangsu Muyang Co., Ltd., Yangzhou 225127, Jiangsu China)
出处 《热处理》 CAS 2017年第1期52-54,共3页 Heat Treatment
关键词 氧化物 淬火裂纹 碳当量 oxides quenching crack carbon equivalent
  • 相关文献

参考文献3

共引文献13

同被引文献41

引证文献5

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;