心血管疾病介入操作时患者受照剂量的分析

Analysis of the Dose of the Patient during the Intervention of Cardiovascular Disease
下载PDF
导出
摘要 目的分析心血管疾病患者介入操作过程中患者的受照剂量情况。方法选择2015年11月至2016年11月期间在我院行心血管介入手术治疗的患者60例,根据手术类别划分为冠状动脉血管造影术(CA)组(单治组)与行冠状动脉的血管造影术(CA)后再行经皮穿刺腔内冠状动脉的成形术(PTCA)组(联合组)2组,通过TLD个人剂量的计照射野矩阵测量方法,对患者最高皮肤的剂量/PSD、荧光照射的时间与入射皮肤的剂量/ESD等指标进行测量。结果荧光的透视时间平均值(17.82±3.16)min,ESD平均值为(159.61±16.54)mGy,PSD平均值为(772.39±85.72)mGy。结论因为辐射容易引发皮肤的损伤,所以需要对最大皮肤的受照剂量进行监测,以对患者组织与器官进行防护。 Objective To analyze the dose of patients undergoing cardiovascular interventional surgery. Methods 60 cases of patients with surgical treatment during the period of 2015 November to 2016 November selected in our hospital for cardiovascular intervention, according to the type of surgery for coronary artery angiography (CA) group (single treatment group) and coronary artery angiography (CA) and then underwent percutaneous transluminal coronary angioplasty (PTCA) group. (joint group) 2 groups, the radiation field matrix measurement method for TLD personal dose, dose time and/ESD index of entrance skin dose/PSD, fluorescence on the skin of the patients with the highest measurement. Results The average fluoroscopy time (17.82±3.16)min, the average value of ESD was (159.61±16.54) mGy, the average value of PSD was (772.39±85.72) mGy. Conclusion Because radiation is easy to cause skin damage, it is necessary to monitor the maximum skin dose in order to protect the patient's tissues and organs.
作者 曹玉梅
出处 《中国医药指南》 2017年第8期7-8,共2页 Guide of China Medicine
关键词 心血管病 介入治疗 受照剂量 Cardiovascular disease Interventional therapy Dose
  • 相关文献

参考文献8

二级参考文献76

  • 1陶永军,陈本宝,徐孝波,傅立军,王红飞.介入放射手术时被检者和操作者受照射剂量调查[J].中华放射医学与防护杂志,2005,25(1):76-77. 被引量:8
  • 2郁鹏,尉可道,李田昌,程玉玺,燕树林,刘澜涛.介入诊疗区域内辐射场的测定与评价[J].中华放射医学与防护杂志,2005,25(3):270-271. 被引量:11
  • 3Balter S.Stray radiation in the cardiac catheterization laboratory[J].Radiat Prot Dosim,2001,94(1-2):183-188.
  • 4International Commission on Radiological Protection.ICRP Publication 89.Avoidance of radiation injuries from medical interventional procedures[R].Oxford:Pergamon Press,2000.
  • 5Farah J,Struelens L,Dabin J,et al.A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists[J].Radiat Prot Dosim,2013,157(4):561-569.
  • 6McVey S,Sandison A,Sutton DG.An assessment of lead eyewear in interventional radiology[J].J Radiol Prot,2013,33(3):647-659.
  • 7Antic V,Ciraj-Bjelac O,Rehani M,et al.Eye lens dosimetry in interventional cardiology:results of staff dose measurements and link to patient dose levels[J].Radiat Prot Dosim,2013,154(3):276-284.
  • 8Carinou E,Ferrari P,Koukorava C,et al.Monte Carlo calculations on extremity and eye lens dosimetry for medical staff at interventional radiology procedures[J].Radiat Prot Dosim,2011,144(1-4):492-496.
  • 9International Commission on Radiological Protection.ICRP Publication 110.Adult reference computational phantoms[R].Oxford:Pergamon Press,2007.
  • 10Bilski P,Bordy JM,Daures.J,et al.The new EYE-DTM dosemeter for measurements of HP (3) for medical staff[J].Radiat Meas,2011,46(11):1239-1242.

共引文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部