期刊文献+

骨质疏松性椎体压缩骨折的Micro-CT影像学参数分析 被引量:11

Evaluation of radiographic parameters in osteoporotic vertebral compression fractures with micro-CT
下载PDF
导出
摘要 目的初步探讨骨质疏松性椎体压缩骨折患者、骨质疏松患者以及无骨质疏松患者3者间椎体骨质的差别。方法对30例需要进行手术治疗的患者进行分组,分别为骨质疏松性椎体压缩骨折患者组、骨质疏松患者组及无骨质疏松患者组,每组10例。在术中分别取出3组患者少许椎体样本,椎体样本大小相等,不影响手术疗效的同时亦不会对患者造成不良影响,患者均表示知情同意。随后分别对取出的椎体标本进行显微计算机断层扫描术(micro-computed tomography,Micro-CT)检测,以了解及对比3组患者之间椎体骨密度(bone mineral density,BMD)、骨矿含量(bone mineral content,BMC)和骨小梁情况。结果骨质疏松性椎体压缩骨折患者组对比骨质疏松患者组、无骨质疏松患者组其椎体皮质骨BMD、松质骨BMD、骨小梁BMD和总体BMD以及皮质骨BMC、松质骨BMC和总BMC均有明显下降,差异具有统计学意义(P<0.05),其中骨小梁BMD、皮质骨BMC、松质骨BMC和总BMC下降显著(P<0.01);骨质疏松患者组对比无骨质疏松患者组其椎体皮质骨BMD、松质骨BMD、骨小梁BMD和总体BMD以及皮质骨BMC、松质骨BMC和总BMC均有下降,差异具有统计学意义(P<0.05),其中骨小梁BMD下降显著(P<0.01)。结论较低的椎体BMD和BMC是椎体压缩骨折发生发展的主要原因,骨质疏松患者和暂无骨质疏松人群需要预防BMD、BMC的下降,防止骨质疏松性椎体压缩骨折的发生。 Objective To preliminarily illustrate the differences in bone quality among patients with osteoporotic vertebral compression fractures( OVCF),patients with osteoporosis,and patients without osteoporosis.Methods Thirty patients who needed to receive spinal operation were divided into 3 groups: OVCF group,osteoporosis( OP) group,and non-osteoporosis( NOP) group( n = 10 in each group).Vertebra samples at equal size were extracted from every patient who had signed informed consent,which would not influence the operation effect.Extracted vertebral samples were undergone micro-computed tomography( micro-CT) to collect information of the bone mineral density( BMD),bone mineral content( BMC),and trabecular structure.Results BMD and BMC of cortical,cancellous,trabecular,and total bone decreased significantly in OVCF patients compared to those in patients of OP and NOP group( P〈0.05).Amongst these parameters,trabecular BMD,cortical BMC,cancellous BMC,and total BMC decreased more significantly( P〈0.01).BMD and BMC of cortical,cancellous,trabecular,and total bone decreased significantly in OP group compared to those in NOP group( P〈0.05),among which trabecular BMD showed the most significant decrease( P〈0.01).Conclusion Relatively lowlevels of BMD and BMC are vital contributing factors to osteoporotic vertebral compression fractures.Patients with osteoporosis should pay attention to prevent decrease in BMD and BMC in order to reduce the risk of osteoporotic vertebral compression fractures.
出处 《中国骨质疏松杂志》 CAS CSCD 北大核心 2017年第3期298-302,共5页 Chinese Journal of Osteoporosis
基金 广东省自然基金项目(2016A030313641) 广州中医药大学中医骨伤科学国家重点学科开放基金资助(YB12) 2016年国家级大学生创新创业训练计划项目(201610572262)
关键词 骨质疏松 椎体压缩骨折 显微计算机断层扫描术 椎体骨质 影像学参数 骨密度 骨矿含量 Osteoporosis Vertebral compression fracture Micro-computed tomography Vertebra quality Radiographic parameters Bone mineral density Bone mineral content
  • 相关文献

参考文献2

二级参考文献42

  • 1[24]Pistoia W,van Rietbergen B, Laib A,et al. High - resolution three dimensional - pQCT images can be an adequate basis for in - vivo microFE analysis of bone. J Biomech Eng,2001,123 :176 - 183.
  • 2[25]M. Ito,A. Nishida, A. Koga. et al. Contribution of trabecular and cortical components to the mechanical properties of bone and their regulating parameters. Bone, 2002,31: 351 - 358.
  • 3[26]S.V.N. Jaecques, L. Murarua, E. De Smet. et al. Micro CT - based finite element analysis:an enhanced follow - up tool for bone remodelling around threaded implants. International Congress Series,2003,1256:1356.
  • 4[27]Jaecques SV,Van Oosterwyck H,Muraru L,et al. Individualized,micro CT- based finite element modelling as a tool for biomechanical analysis related to tissue engineering of bone. Biomaterials, 2004,25:1683 - 1696.
  • 5[28]Angela S. P. Thomas H, Sarah H. et al. Microarchitectural and mechanical characterization of oriented porous polymer scaffolds. Biomaterials, 2003,24:481 - 489.
  • 6[29]Koichi Morimoto,Takahiko Shimizu,Kiyoshi Furukawa,et al. Transgenic expression of the EXT2 gene in developing chondrocytes enhances the synthesis of heparan sulfate and bone formation in mice.Biochemical and Biophysical Research Communications,2002,292:999 - 1009.
  • 7[30]Terakado M, Hashimoto K, Arai Y, et al. Diagnostic imaging with newly developed ortho cubic super - high resolution computed tomography (Ortho- CT). Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2000,89:509 - 518.
  • 8[31]Yoshinori Arai, Kazuya Honda, Kazuo Iwai, et al. Practical model "3DX" of limited cone -beam X -ray CT for dental use, International Congress Series, 2001,1230: 713 - 718.
  • 9[32]Ayuta Yamada,Hitoshi Tsunashima,Yoshinori Arai,et al. Generation of 3- D solid model from 3DX multi -image micro- CT( methods and application), International Congress Series, 2003,1256:1224 -1229.
  • 10[33]Audrey L. Hildebrandt, Dawn M. Kelly - Sullivan, Shawn C. Black,et al. Validation of a high - resolution X - ray computed tomography system to measure murine adipose tissue depot mass in situ and longitudinally. Journal of Pharmacological and Toxicological Methods,2002,47:99 - 106.

共引文献86

同被引文献82

引证文献11

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部