摘要
化工行业事故废水收集系统包括罐区及装置区围堰、收集管网和应急事故水池。文章重点论述了事故废水收集系统的管网设置要求以及应急事故水池的容积计算及设置要求,并提出了设计过程中存在的问题。
The accident waste water collection system in chemical industry includes tank area and installation area cofferdam, collecting pipe network and emergency accident pool. This paper focuses on the design of the pipe network of the accident waste water collection system and the volume calculation and setting requirements of the emergency accident pool, and puts forward the problems in the design process.
作者
孙晨
贺慧宁
周虹
严美霞
Sun Chen He Huining Zhou Hong Yan Melxia(China National Air Separation Engineering Co. , Ltd. , Hangzhou 310051, China Zhejiang Zhongchenxin Engineering Technology Co. , Ltd. , Hangzhou 310011, China)
出处
《山东化工》
CAS
2017年第7期213-214,共2页
Shandong Chemical Industry
关键词
应急事故水池
收集系统
容积
设置要求
emergency accident pool
collection system
volume
setting requirements