期刊文献+

湿法电除尘系统处理焦化厂拦焦烟尘 被引量:2

Removal of coke retention dust by wet electrostatic precipitation system
原文传递
导出
摘要 针对焦化厂烟尘高浓度、高温、高湿和高黏度的特征,采用湍流预洗涤塔和湿法电除尘器处理拦焦烟尘。通过中试实验采样分析,利用全因子设计考察烟气流量、湍流预洗涤塔填料高度和喷淋流量对系统除尘效果的影响。实验表明,填料高度和喷淋流量是影响除尘效果的显著项,拦焦烟尘经过湿法电除尘系统的处理,烟尘浓度为8.3 mg·m^(-3),系统除尘率达到99.9%。 A turbulent pre-scrubber and wet electrostatic precipitator were used to dispose of coke plant dust with the characteristics of high temperature,high concentration,high humidity,and high viscosity. The effects of dust flow,packing amount,and spraying flow on dust removal were studied by full factorial design in the pilot test. The results showed that the packing amount and spraying flow were the significant factors,and the final dust concentration and removal efficiency were 8. 3 mg·m^-3 and 99. 9%,respectively.
出处 《环境工程学报》 CAS CSCD 北大核心 2017年第4期2337-2342,共6页 Chinese Journal of Environmental Engineering
基金 国家科技支撑计划项目(2013BAC14B03)
关键词 拦焦烟尘 湍流预洗涤塔 湿法电除尘 除尘率 coke retention dust turbulent pre-scrubber wet electrostatic precipitation dust removal efficiency
  • 相关文献

参考文献9

二级参考文献117

共引文献737

同被引文献14

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部