摘要 目的分析磁共振成像技术在膝关节软骨损伤诊断中的应用价值。方法选取膝关节软骨损伤患者61例(74膝),于关节镜前实施磁共振成像技术诊断,评价磁共振成像技术在膝关节软骨损伤诊断中的应用价值。结果磁共振诊断结果中膝关节软骨损伤0级、Ⅰ级、Ⅱ级、Ⅲ级、Ⅳ级个数与关节镜检查结果比较,差异无统计学意义(P>0.05);磁共振诊断的灵敏度为97.07%。结论磁共振成像技术诊断膝关节软骨损伤具有较高的敏感度、准确度及特异度,有助于提高早期诊断的准确度,具有临床推广价值。
作者 李志彬
出处 《医疗装备》 2017年第8期9-10,共2页 Medical Equipment
  • 相关文献

参考文献8

二级参考文献130

  • 1Recht MP, Kramer J, Marcelis S, et al. Abnormalities of articular carti- lage in the knee : analysis of available MR techniques [ J ]. Radiology, 1993,187 ( 2 ) :473 - 478.
  • 2Disler DG, McCauley TR, Wirth CR, et al. Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging:comparison with standard MR imaging and correlation with arthroseopy [ J ]. AJR Am J Roentgenol, 1995,165 ( 2 ) : 377 - 382.
  • 3Widuchowski W, Widuchowski J, Trzaska T. Articular cartilage defects : study of 25,124 knee arthroscopies [J]. Knee, 2007,14 ( 3 ) : 177 - 182.
  • 4Crema MD, Roemer FW, Marra MD, et al. Articular cartilage in the knee:current MR imaging techniques and applications in clinical practice and research[J]. Radiographics,2011,31 ( 1 ) :37 - 61.
  • 5Kijowski R,Blankenbaker DG,Davis KW,et al. Comparison of 1.5- and 3.0-T MR imaging for evaluating the articular cartilage of the knee joint [ J ]. Radiology,2009,250 ( 3 ) : 839 - 848.
  • 6Ghazinoor S, Crues JV 3rd, Crowley C. Low-field musculoskeletal MRI [J]. J Magn Reson Imaging,2007,25 ( 2 ) : 234 - 244.
  • 7Rossler E,Mattea C,Mollova,A,et al. Low-field one-dimensional and direction-dependent relaxation imaging of bovine articular cartilage[J]. J Magn Reson,2011,213( 1 ) :112 - 118.
  • 8Jungius KP, Schmid MR, Zanetti M, et al. Cartilaginous defects of the femorotibial joint : accuracy of coronal short inversion time inversion-re- covery MR sequence [ J ]. Radiology, 2006,240 ( 2 ) :482 - 488.
  • 9Roemer FW,Guermazi A,Lynch JA,et al. Short tau inversion recovery and proton density-weighted fat suppressed sequences for the evaluation of osteoarthritis of the knee with a 1.0 T dedicated extremity MRI : de- velopment of a time-efficient sequence Protocol[ J]. Eur Radiol,2005, 15(5) :978 -987.
  • 10Disler DG, McCauley TR, Kelman CG, et al. Fat-suppressed three-di- mensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee:comparison with standard MR imaging and arthrosco- PY [ J ]. A JR Am J Roentgenol, 1996,167 ( 1 ) : 127 - 132.