300MW亚临界机组节能改造技术路线简述 被引量:2

The description of energy reconstruction for 300MW subcritical units
下载PDF
导出
摘要 2015年国家发改委164号文件提出火电机组超低排放和节能改造的要求,从节能降耗的角度出发,文中研究了国内亚临界300MW机组节能改造的各种技术方法,评价了各种方法的节能效果,综合得出了合理的节能改造技术路线,从而开创我国火电机组节能降耗的新局面。 Ultra-lowemission and energy efficiency renovation were put forward for thermal power unit energy consumption level in document No.164 2015 of National Development and Reform Commission.From the view point of energy saving and reducing consumption,various methods of energy efficiency renovation of 300 MW subcritical power units are studied in the paper,the energy saving effect of various methods are evaluated,then a comprehensive energy saving technology route is put forward.This will make a breakthrough for energy saving in Chinese thermal power plants.
出处 《节能》 2017年第3期54-57,共4页 Energy Conservation
关键词 亚临界300MW 节能改造 技术路线 thermal power units energy saving reconstruction technique route