期刊文献+

直流供水系统中虹吸井设计优化分析——以某发电厂为例 被引量:2

Design Optimication Analysis Of Siphon Well In DC Water Supply System:Taking the Power Plant for an Example
下载PDF
导出
摘要 虹吸井是电厂供水流程中非常重要的一部分,虹吸井的设置可降低循环水泵的扬程,节约电耗。设计基于某电厂工程资料,通过实验室模拟选型,从虹吸井占地尺寸、虹吸的有效利用高度、建设的投资费用、水流流态,以及电厂的经济运行等方面综合分析,得出了虹吸井的优化尺寸。 Siphon well is a very important part in the process of power plant water supply, it can reduce the lift of circulating pump, save power consumption.Based on data of apower plant, through laboratory simulation model ,study on the dimension, effective siphon height,instruction cost of the siphon well, flow pattern of water, and the economic operation pattern of the power plant, an optimization size of the siphon well is obtained.
作者 沈冬梅 余才锐 吴少扬 Shen Dong-mei Yu Cai-rui Wu Shao-yang(West Anhui University Lu'an Anhui, 237012, China Central Southern China Electric Power Design Institute (CSEPDI) of China Power Engineering Consulting Group Corporation,WuhanHubei 430071,China)
出处 《铜陵学院学报》 2017年第1期99-101,114,共4页 Journal of Tongling University
基金 皖西学院校级重点项目(KJ103762015B13)
关键词 虹吸井 水流条件 虹吸高度 优化研究 siphon well flow pattern siphon height optimization study