摘要 医用硬性内窥镜照明有效性检测是评价医用硬性内窥镜光学系统照明光路效果的质量优劣的一个重要指标参数。由此,也可以用照明有效性来作为光学镜照明光路质量评价方法。本文依据YY0068.1-2008行业标准,对硬性光学内窥镜的照明有效性测量和计算方法进行叙述,同时,还结合标准定义给出照明有效性中两个指标边缘均匀性和照明镜体光效的公式意义,以便读者对新概念的理解和检测。 The establishment of medical rigid endoscope Testing Method Research of lighting effectiveness,quality of endoscope illumination effect mirror optical system of medical rigid inside, is a very important parameter. It can also be used as effective lighting optics illumination quality evaluation method. In this paper,according to the standard of YY 0068.1-2008,the rigid optical endoscope lighting effectiveness measurement and calculation method are described. At the same time, combined with the standard two indicators are defined in the validity of edge lighting uniformity and lighting mirror light effect formula of significance, for the new concept of understanding and testing.
作者 黄志强 王海娟 丁罕 HUANG Zhi-qiang WANG Hai-juan DING Han(Guangdong Medical Devices Quality Surveillance and Test Institute (Guangdnng Guangzhou 510663)
出处 《中国医疗器械信息》 2017年第13期44-45,63,共3页 China Medical Device Information
关键词 硬性内窥镜 照明有效性 边缘均匀性 照明镜体光效 medical rigid endoscope lighting effectiveness edge uniformity relative self-effect of illumination light luminosity