摘要
对常州轨道交通1号线信号维护监测子系统现状进行了简要介绍。以道岔转辙机和信号机为例,对传统国产计算机联锁与信号维护监测子系统的继电器接口方案进行了介绍,重点介绍了庞巴迪Ebilock950全电子联锁与国产信号维护监测子系统的接口方案,可作为类似项目设计的参考方案。
The status of the maintenance and monitoring system of Changzhou rail transit Line 1 signaling system are briefly introduced. The switch machine and signal machine are taken as examples to describe the relay interface program of traditional computer interlocking and maintenance monitoring subsystem. Bombardier Ebilock-950 all-electronic interlock and domestic maintenance monitoring subsystem interface program are specially talked about. This research can be used as a reference design for similar projects.
出处
《城市轨道交通研究》
北大核心
2017年第B08期57-59,共3页
Urban Mass Transit
关键词
轨道交通
计算机联锁
信号维护监测子系统
道岔转辙机
接口方案
rail transit
computer interlocking
signal main-tenance and monitoring subsystem
switch machine
interface program