期刊文献+

明胶海绵封堵在单侧穿刺经皮椎体后凸成形术的应用 被引量:2

Application of gelatin sponge plugging in unilateral puncture percutaneous kyphoplasty
下载PDF
导出
摘要 目的:研究明胶海绵封堵对单侧穿刺经皮椎体后凸成形术(PKP)疗效的影响。方法:对60例骨质疏松性压缩性骨折(OVCF)患者行经皮椎体后凸成形术治疗,根据操作方法不同分为明胶海绵封堵组(联合组)和常规对照组(对照组)。观察2组手术时间、骨水泥注入量,手术前后疼痛视觉模拟评分(VAS)、椎体平均高度、骨水泥弥散系数,骨水泥渗漏等指标并加以分析。结果:全部病例随访6~12个月,对照组术前VAS评分为(6.58±1.57)分,末次随访VAS评分为(2.78±1.24)分;联合组术前VAS评分为(6.39±0.97)分,末次随访VAS评分(2.56±1.38)分;2组患者手术前后比较,差异有统计学意义(P<0.05)。对照组术前伤椎高度平均为(20.6±4.3)mm,术后为(29.7±3.2)mm;联合组术前伤椎高度平均为(21.3±3.5)mm,术后为(30.7±4.0)mm,2组患者手术前后比较差异有统计学意义(P<0.05);对照组术后X片测量骨水泥弥散系数为(57.3±8.7)%,联合组为(74.7±7.6)%,2组比较差异有统计学意义(P<0.05)。结论:明胶海绵封堵对单侧穿刺椎体后凸成形术后疗效无明显影响,但可以有效减少骨水泥渗漏的发生,改善骨水泥在椎体内的弥散。 Objective: To investigate the therapeutic effect of gelatin sponge plugging in unilateral puncture percutaneous kyphoplasty (PKP).Methods: 60 cases of patients with osteoporotic vertebral compression fracture (OVCF) underwent KPK and then were divided into a gelatin sponge plugging group (combination group) and a routine treatment group (control group).The two groups were obseved and analyzed in terms of indexes such as operation time,bone cement infusion volume,VAS scores,mean vertebral height,diffusion coefficient of bone cement,and bone cement leakage.Results: All the cases were followed up 6 ~ 12 months.The preoperative VAS scores and the last follow-up VAS scores of the control group were (6.58 ± 1.57) and (2.78 ± 1.24) respectively,in contrast with the combination group's (6.39 ± 0.97) and (2.56 ± 1.38).The pre-and post-operative differences of the two groups were of significance (P 0.05).The pre-and post-operative mean wounded vertebral heights of the control group were (20.6 ± 4.3) and (29.7 ±3.2) respectively,while the combination group's were (21.3 ± 3.5) and (30.7 ± 4.0).The pre-and post-operative differences of the two groups were statistically significant (P 0.05).The post-operative bone cement diffusion coefficient was (57.3 ± 8.7) % for the control group and (74.7 ± 7.6) % for the combination group.There was statistic significance (P 0.05).Conclusion: Gelatin sponge plugging used in unilateral puncture percutaneous kyphoplasty has no significant influence on the post-operative curative effect,but it can effectively reduce the bone cement leakage and improve the diffusion of bone cement in vertebrae.
出处 《淮海医药》 CAS 2017年第5期511-514,517,共5页 Journal of Huaihai Medicine
基金 蚌埠市科技局2014年科技立项(201400115)
关键词 骨质疏松 椎体压缩性骨折 经皮椎体后凸成形术 骨水泥 Osteoporosis Vertebral compression fracture Percutaneous kyphoplasty Bone cement
  • 相关文献

参考文献4

二级参考文献60

  • 1李左安,邵增务.骨质疏松性骨折外科治疗新进展[J].国际骨科学杂志,2007,28(2):114-116. 被引量:17
  • 2Barr JD,Barr MS,Lemley TJ. Percutaneous vertebroplasty for pain relied and spinal stabilization[J].{H}SPINE,2009,(05):923-928.
  • 3Cotton A,Boutry N,Cortet B. Percutaneous vertebroplasty:state of the art[J].{H}RADIOGRAPHICS,2008,(02):311-320.
  • 4Giovanni Carlo Anselmetti,Antonio Manca,Joshua Hirsch,Filippo Montemurro,Giancarlo Isaia,Giangiacomo Osella,Gabriele Chiara,Gabriella Iussich,Felicino Debernardi,Daniele Regge.Percutaneous Vertebroplasty in Osteoporotic Patients: An Institutional Experience of 1,634 Patients with Long-Term Follow-Up[J].Journal of Vascular and Interventional Radiology.2011(12)
  • 5Antoine G. Tohmeh,John M. Mathis,David C. Fenton,Alan M. Levine,Stephen M. Belkoff.Biomechanical Efficacy of Unipedicular Versus Bipedicular Vertebroplasty for the Management of Osteoporotic Compression Fractures[J].Spine.1999(17)
  • 6Corcos G, Dbjay J, Mastier C, et al. Cement leakage in percutaneous vertebroplasty for spinal metastases: a retrospective evaluation of incidence and risk factors. Spine (Phila Pa 1976), 2014, 39(5): E332-338.
  • 7Ha KY, Lee IS, Kim KW, et al. Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts. ] Bone Joint Surg (Br), 2006, 88(5): 629-633.
  • 8Xing D, Ma JX, Ma XL, et al. A meta-analysis of balloon te/phoplasty compared to percutaneous vertebroplasty for treating osteoporotic vertebral compression fractures. J Clin Neurosci, 2013, 20(6): 795-803.
  • 9Anselmetti GC, Zoarski G, Manca A, et al. Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures. Cardiovasc Intervent Radiol, 2008, 31(5): 937-947.
  • 10Baroud G, Crookshank M, Bohner M. High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage. Spine (Phila Pa 1976), 2006, 31(22): 2562-2568.

共引文献87

同被引文献33

引证文献2

二级引证文献4