期刊文献+

大岗山电站水导瓦温偏高分析及处理 被引量:3

Analysis and Treatment of Abnormal High Temperature of the Turbine Guide Bearing in Dagangshan Hydropower Station
下载PDF
导出
摘要 通过对大岗山水电站水导瓦温偏高处理方法的探讨,采用调整瓦隙和冷却系统改造等,有效地降低了瓦温,减小了不同轴瓦的温差,从而有效地降低了水轮机水导轴承瓦温过高引起的事故发生率,保证了机组安全稳定运行。 The abnormal high temperature problem found in the turbine guide bearing in Dagangshan Hydropower Station is discussed. The treatment measures are introduced, including the adjustment of the bearing clearance and the renova- tion of the cooling system. After the treatment, the bearing temperature and the temperature difference between different bearing pads are effectively reduced. Thus, the safe and stable operation of the unit is ensured.
作者 邓尧曦 戴振宇 韩军 DENG Yaoxi DAI Zhenyu HAN Jun(China Guodian Dadu River Maintenance and Installation Co. , Ltd. , Chengdu 610016, China)
出处 《水电与新能源》 2017年第9期66-70,共5页 Hydropower and New Energy
关键词 大岗山电站 水导瓦 瓦温过高 处理 Dagangshan Hydropower Station turbine guide bearing abnormal high bearing temperature treatment
  • 相关文献

参考文献7

二级参考文献3

  • 1GB/T8564-2003.水轮发电机组安装技术规范[S].[S].,..
  • 2全玲琴.水轮机及其辅助设备[M].北京:中国水利水电出版社,2006.
  • 3郑源,鞠小明,程云山.水轮机[M].北京:中国水利水电出版社,2006.

共引文献21

同被引文献19

引证文献3

二级引证文献2

相关作者