摘要 交直流混联配电系统的稳定性分析方法是评价系统能否安全稳定运行的关键技术。传统稳定性分析方法通常以直流级联系统和直流微电网作为研究对象,而对于含恒功率负载的交直流混联配电系统稳定性分析和评价较少涉及。基于这一问题,提出了适用于交直流混联配电系统的阻抗匹配稳定性分析方法,建立了柔性互联装置、光伏发电单元、恒功率负载以及?型线路的状态空间小信号模型。在多端柔性互联装置采用主从和下垂控制情况下构建了交直流混联配电系统的戴维南等效电路,利用奈奎斯特稳定判据确定了负阻抗稳定边界,并且采用Simulink仿真工具搭建了详细物理模型,通过仿真结果和奈奎斯特曲线对比分析验证了所提稳定性分析方法的可行性。 The stability analysis method of AC/DC hybrid distribution system is the key technology to evaluate whether the system can operate safely and stably. Traditional stability analysis methods are usually based on the DC cascade system and DC microgrid as the research object, and the stability analysis and evaluation of AC/DC hybrid distribution systems with constant power loads are rarely involved. Based on this problem, the stability analysis method based on impedance matching was proposed for AC/DC hybrid distribution system, state space small signal model of flexible interlinking device, photovoltaic power generation unit, constant power load and line were established. Thevenin equivalent circuits of AC/DC hybrid distribution system were established when the master-slave control and droop control were used for multi-terminal flexible interlinking device. The negative impedance stability boundary was determined by the Nyquist stability criterion, and the detailed physical model was built by the Simulink simulation tools. Finally, the feasibility of the proposed stability analysis method was verified by comparison analysis of simulation results and the Nyquist curves.
出处 《中国电机工程学报》 EI CSCD 北大核心 2017年第19期5572-5582,共11页 Proceedings of the CSEE
基金 国家863高技术基金项目(2015AA050102) 国家自然科学基金项目(51407177) 国家电网公司科技项目(DZ71-16-001)~~
关键词 交直流混联配电系统 恒功率负载 小信号模型 稳定性分析 柔性互联装置 AC/DC hybrid distribution system constantpower load small signal model stability analysis flexibleinterlinking device
  • 相关文献

参考文献8

二级参考文献248

  • 1陈海荣,徐政,张静.一种基于电压源型多端直流输电的供电系统[J].高电压技术,2006,32(9):1-5. 被引量:24
  • 2陈海荣,徐政.适用于VSC-MTDC系统的直流电压控制策略[J].电力系统自动化,2006,30(19):28-33. 被引量:122
  • 3高朝晖,林辉,张晓斌.Boost变换器带恒功率负载状态反馈精确线性化与最优跟踪控制技术研究[J].中国电机工程学报,2007,27(13):70-75. 被引量:52
  • 4袁旭峰,文劲宇,程时杰.多端直流输电系统中的直流功率调制技术[J].电网技术,2007,31(14):57-61. 被引量:35
  • 5Izquierdo D, Azcona R, del Cerro F, et al. Electrical power distribution system (HV270DC), or application in more electric aircraft[C]//Proceedings of Applied Power Electronics Conference and Exposition (APEC) 2010 Twenty-FifthAnnual. Palm Springs, USA. IEEE, 2010: 1300-1305.
  • 6Jusoh A B. The instability loads[C]//Proceedings of Conference. Kuala Lumpur, 175-179. effect of constant power Power and Energy Malaysia: IEEE, 2004:.
  • 7Emadi A, Fahimi B, Ehsani M. On the concept of negative impedance instability in the more electric aircraft power systems with constant power loads[C]//34th Intersociety Energy Conversion Engineering Conference. Savannah, USA~ ASME, 1999: 689-699.
  • 8Emadi A, Khaligh A, Rivetta C H, et al. Constant power loads and negative impedance instability in automotive systems: definition, modeling, stability, and control of power electronic converters and motor drives[J]. IEEE Transactions on Vehicular Technology, 2006, 55(4): 1112-1125.
  • 9Middlebrook R D. Input filter considerations in design and application of switching regulators[C]//Proceedings of IEEE IASAM, Pasadena, USA: IEEE, 1976: 366-382.
  • 10Liutanakul P, Awan A B, Pierfederici S, et al. Linear stabilization of a DC bus supplying a constant power load: a general design approach[J]. IEEE Transactions on Power Electronics, 2010, 25(2): 475-488.

共引文献1043

同被引文献506

引证文献45

二级引证文献484

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部