本文对常用的几种蒸发冷却水机组的结构类型进行总结,并对这几种蒸发冷却冷水机组的参数进行了对比,最后进行实验数据分析,得出表冷间接-直接蒸发冷却冷水机组,管式间接-直接蒸发冷却冷水机组,露点间接-直接蒸发冷却冷水机组的出水温约为16~18℃,满足温湿度独立控制空调系统中的要求。
The structure of the commonly used several kinds of evaporation cooling water unit was summarized, and the parameters of several kinds of evaporative cooling water chillers are compared. After analyzed experiment data, it was found that the outlet water temperature of surface cold indirectly-direct evaporative cooling water chillers, tubular indirect-direct evaporative cooling water chillers, dew point indirect-direct evaporative cooling water chillers all is about 16-18 ℃, which meets the requirement of temperature and humidity independent control air conditioning system.
作者
褚俊杰
黄翔
杜冬阳
武以闯
CHU Jun-jie HUANG Xiang DU Dong-yang WU Yi-chuang(School of Environmental & Chemical Engineering, Xi'an Polytechnic Universit)
出处
《建筑热能通风空调》
2017年第10期38-41,共4页
Building Energy & Environment
基金
"十三五"国家重点研发计划项目课题(2016YFC0700404)
关键词
蒸发冷却温湿度独立控制空调系统
蒸发冷却冷水机组
测试
对比
evaporative cooling temperature and humidity independent control air conditioning system, evaporative cooling water chiller, experiment