摘要
通过对丰满地震台雷击危害隐患分析,根据台站的实际情况,采取区域防雷、电源进线防雷、通信传输线防雷、传感器引线防雷等技术,完成台站综合观测技术保障系统建设。技术系统建成并经过两年雷雨期检验,防雷效果明显,同时不断总结积累维护经验,确保防雷保障系统发挥最佳效能。
By analysis of lightning stroke hazard to Fengman seismic station,station comprehensive observation technology support system construction is completed by taking the regional lightning protection,power supply line lightning protection,communication transmission line lightning protection,sensor lead lightning protection technology.The technical system has been tested for two years in thunderstorm period,and the effect is obvious.At the same time,maintenance experience is summarizing constantly to ensure the best efficiency of lightning protection system.
出处
《山西地震》
2017年第4期31-33,共3页
Earthquake Research in Shanxi
基金
吉林省地震局合同制科研课题(5)
地震行业科研专项结余资金使用计划项目(2060302)联合资助
关键词
雷击灾害
综合防雷
系统维护
Lightning disaster
Synthetical lightning protection
System maintenance