期刊文献+

盘锦红25井和于105井水温梯度观测试验及其结果分析 被引量:3

Observation Experiment and Its Results Analysis of Panjin Hong 25 Well and Yu 105 Well Water Temperature Gradient
下载PDF
导出
摘要 对盘锦地震台红25井和于105井水温梯度进行精密测量并对水温梯度特征进行分析。结果表明,观测井不同深度上的水温变化形态有一定的相似性,水温稳定过程均呈对数曲线变化,且两口井水温梯度曲线变化具有一致性特征,其温度—深度曲线几乎重合,但井孔不同深度的井水温度微动态特征明显,显示出一定的差异性。结合井孔柱状图与区域水文地质资料综合分析认为,差异性变化主要与井孔的水文地质特征、地下水类型有关。根据对井孔水温梯度数据的分析确定了水温探头投放的最佳位置。 A file for Panjin seismic Hong 25 wells and the well water temperature gradient in Yu 105 precision measurement and analysis the characteristic of temperature gradient.The results show that,Observation well water temperature in different depth change form has a certain similarity,Water temperature stable process a logarithmic curve changes,Two wells water temperature gradient curve and has the characteristics of consistency,Its temperature depth curve almost overlap,but different depth hole section of well water temperature dynamic characteristics significantly,showing a certain difference.Combined with the well bore log chart and regional hydrogeology data comprehensive analysis think,difference change main hydrogeological characteristics、groundwater with hole type.According to the analysis of borehole water temperature probe into the best position.
出处 《防灾减灾学报》 2017年第4期66-69,共4页 Journal of Disaster Prevention And Reduction
基金 中国地震局监测 预测 科研三结合课题(160604)
关键词 红25井 于105井 水温梯度 水文地质 探头位置 Hong 25 well Yu 105 well water gradient hydrogeology probe location