期刊文献+

柴油加氢装置过程模拟与节能研究 被引量:5

Process Simulation and Energy Saving Method of Diesel Hydrotreating Unit
下载PDF
导出
摘要 针对某炼油厂处理量为3.5 Mt/a的柴油加氢装置,应用Aspen Plus流程模拟软件建立了装置的数学模型,计算得出了与现场标定数据比较吻合的模拟结果。根据计算结果,利用夹点技术对其换热网络进行节能分析与改造。首先以夹点温差为20℃,确定换热网络能量目标。该装置换热网络的夹点温度为95.4℃,最小热公用工程量为5 085.7 kW,最小冷公用工程量为20 613.9 kW,与现有换热网络热公用工程13 870.8 kW相比,存在8 785.1 kW的节能潜力。然后消除违背夹点规则的不合理换热匹配,进一步优化,并提出了改造方案。该方案新增7台换热器,可节约热公用工程8 450.5 kW,约降低了60.9%的能耗,取得了良好的节能效果。回收期为0.67年。 Aiming at 3.5 Mt/a diesel hydrotreating unit in a refinery, the mathematical model of the device was established by Aspen Plus software, simulated results obtained by calculation were consistent with field calibration data. Based on calculation results, its heat exchanger network(HEN) was retrofitted by pinch analysis. When the pinch temperature difference was 20 ℃, energy target of the HEN was determined. The pinch temperature of the HEN in the unit was 95.4 ℃, the minimum thermal utility quantity was 5 085.7 kW, the minimum cold utility quantity was 20613.9 kW, compared with 13 870.8 kW thermal utility quantity of the HEN, there was energy-saving potential of 8785.1 kW. In order to eliminate irrational heat transfer matching that breached the pinch rule, the modification plan was put forward. In the plan, seven new heat exchangers were added, thermal utility quantity 8 450.5 kW was saved, the energy consumption was decreased by 60.9%.
出处 《当代化工》 CAS 2017年第12期2538-2542,共5页 Contemporary Chemical Industry
基金 国家自然科学基金项目 项目号:21406124
关键词 夹点技术 换热网络 柴油加氢 节能 Pinch technology Heat exchanger network Diesel hydrotreating process Energy saving
  • 相关文献

参考文献6

二级参考文献44

共引文献41

同被引文献48

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部