期刊文献+

液晶显示器运动模糊测量方法及研究进展

Motion blur measurement method and research progress of liquid crystal display
下载PDF
导出
摘要 运动模糊是影响显示图像质量的关键问题之一,对液晶显示器(LCD)运动模糊进行了详细的综述。首先概述了运动模糊的成因及改善方案,然后介绍了两类运动模糊测量方法:直接测量法、间接模拟法。直接测量法包括人眼主观评价法、高速相机法、追踪相机法、旋转镜面法、亮度计测量法等;间接模拟法利用灰阶亮度响应时间、模糊图像等基础数据进行仿真,选取不同的数学模型模拟人眼的平滑追踪、亮度时域积分。详细分析了各种检测方法的特点,最后进行归纳总结。 Motion blur is one of the key problems that affect the quality of display images. In this paper,motion blur of liquid crystal display( LCD) is reviewed in detail. First,the causes of motion blur and improvement scheme are introduced. Then,two kinds of motion blur measurement methods are introduced: direct measurement method and indirect simulation method. Direct measurement method including the subjective evaluation of the human eye,high-speed camera method,tracking camera method,rotating mirror method,brightness meter measurement method; indirect simulation method using gray-scale brightness response time,fuzzy image and other basic data simulation the human eye's smooth tracking and brightness time domain integration. The characteristics of various measurement methods are analyzed in detail,and the conclusion is summarized.
出处 《电视技术》 北大核心 2017年第7期175-181,共7页 Video Engineering
基金 国家质检总局科技计划项目(2015QK160) 广东省科技计划项目(2015A030401058)
关键词 LCD 运动模糊 运动图像响应时间 动态图像质量 LCD motion blur moving-picture response time (MPRT) moving-picture quality
  • 相关文献

参考文献9

二级参考文献65

  • 1张昱,张健.基于多项式曲面拟合的TFT-LCD斑痕缺陷自动检测技术[J].光电工程,2006,33(10):108-114. 被引量:19
  • 2宋文,李晓华,杨晓伟.平板显示器中运动模糊的测量分析[J].真空科学与技术学报,2007,27(2):105-108. 被引量:5
  • 3FPDM update file of flat panel display measurement standard version 2. 0 [ R ]. FPDM Task Group of Video Electronics Standard Association, 2005:1-18.
  • 4SOMEYA J, LGARASHI Y. A review of MPRT measurement method for evaluating motion blur of LCDs [ C ]. IDW'04 Digest, 2004 : 1571-1574.
  • 5KURITA T. Moving picture quality improvement for holdtype AM-LCDs[ C ]. SID 01 Digest, 2001:986-999.
  • 6SASAKI D. Motion picture simulation for designing High- Picture-Quality Hold-Type Displays[ C]. SID 02 Digest, 2002 : 926 -929.
  • 7LI X H. LCD motion artifact determination using simulation methods[ C]. SID 06 Digest, 2006:6-10.
  • 8SONG W. Motion-blur characterization on liquid-crystal display[ J]. Journal of the SID 16/5, 2008:587-593.
  • 9KIM S S. Advancements for highest-performance LCD-TV [ C]. SID'06, 2006:1938-1941.
  • 10SLUYERMAN A A S. Architectural choices in a scanning backlight for large LCD TVs [ C ]. SID05 Digest, 2005 : 996 -999.

共引文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部