期刊文献+

Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial 被引量:1

Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial
原文传递
导出
摘要 AIM: To compare characteristics of preloaded and nonpreloaded intraocular lens(IOL) delivery systems during IOL delivery procedures. METHODS: Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including i Sert250 NC60(NC60), En Vista MX60(MX60), Acry Sof IQ SN60 WF(SN60 WF), TECNIS ZCB00(ZCB00), and TECNIS PCB00(PCB00) were investigated. NC60 and PCB00 were injected via preloaded delivery systems and other IOLs were injected via nonpreloaded systems. In the human trial, time taken from IOL loading to completion of implantation was measured in all eyes undergoing conventional cataract surgery. Using 4 excised porcine eyes, dynamics of ophthalmic viscosurgical device(OVD) between an IOL injector and a porcine eye was analyzed using fluorescein sodiumstained OVD. RESULTS: The average time for IOL implantation was 22.0 s for NC60, 43.2 s for MX60, 32.3 s for SN60 WF, 41.4 s for ZCB00, and 14.6 s for PCB00 respectively. The number of cases with IOL manipulation with a second instrument was 6 for MX60, 2 for ZCB00, 0 for SN60 WF, NC60, and PCB00. Amount of OVD pushed into a porcine eye was smaller with a preloaded system than with non-preloaded systems. CONCLUSION: IOL delivery with preloaded systems is faster and more predictable. Moreover, a preloaded delivery system shows relatively less OVD pushed into a porcine eye than non-preloaded systems. AIM: To compare characteristics of preloaded and nonpreloaded intraocular lens(IOL) delivery systems during IOL delivery procedures. METHODS: Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including i Sert250 NC60(NC60), En Vista MX60(MX60), Acry Sof IQ SN60 WF(SN60 WF), TECNIS ZCB00(ZCB00), and TECNIS PCB00(PCB00) were investigated. NC60 and PCB00 were injected via preloaded delivery systems and other IOLs were injected via nonpreloaded systems. In the human trial, time taken from IOL loading to completion of implantation was measured in all eyes undergoing conventional cataract surgery. Using 4 excised porcine eyes, dynamics of ophthalmic viscosurgical device(OVD) between an IOL injector and a porcine eye was analyzed using fluorescein sodiumstained OVD. RESULTS: The average time for IOL implantation was 22.0 s for NC60, 43.2 s for MX60, 32.3 s for SN60 WF, 41.4 s for ZCB00, and 14.6 s for PCB00 respectively. The number of cases with IOL manipulation with a second instrument was 6 for MX60, 2 for ZCB00, 0 for SN60 WF, NC60, and PCB00. Amount of OVD pushed into a porcine eye was smaller with a preloaded system than with non-preloaded systems. CONCLUSION: IOL delivery with preloaded systems is faster and more predictable. Moreover, a preloaded delivery system shows relatively less OVD pushed into a porcine eye than non-preloaded systems.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第1期6-11,共6页 国际眼科杂志(英文版)
基金 Supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) by the Ministry of Education, Science and Technology (No.NRF2016R1A2B4009626)
关键词 预装的 intraocular 透镜交货系统 非预装的 intraocular 透镜交货系统 intraocular 透镜交货时间 眼的 viscosurgical 设备 preloaded intraocular lens delivery system non-preloaded intraocular lens delivery system intraocular lens delivery time ophthalmic viscosurgical device
  • 相关文献

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部