期刊文献+

三维激光扫描仪的测距与水平角精度评定 被引量:3

Accuracy Assessment of Distance and Horizontal Angle Measurement Based on Terrestrial Laser Scanner
下载PDF
导出
摘要 以三维激光扫描仪Focus^(3D)X130为研究对象,通过实验验证了距离和水平角检校方法的可行性。由精度检校实验得出Focus^(3D)X130测距精度为5mm,测角精度0.0101°,与厂家提供的标称精度有一定误差。因此,在使用三维激光扫描仪之前进行测距和水平角精度的评定和校正将对后续扫描的精度产生一定影响。 This paper takes the 3D laser scanner Focus3DX130 as the research object,and verifies the feasibility of the distance and horizontal angle calibration by experimental design.Through the experiment,the ranging accuracy of Focus3DX130 is found to be 5mm and measuring horizontal angle accuracy is 0.0101°,which are larger than the nominal accuracy provided by manufacturer.Before using the three-dimensional laser scanner,the calibration of ranging and horizontal angle accuracy will have some effects on the follow-up scanning accuracy.
机构地区 东北林业大学
出处 《工具技术》 2018年第2期108-112,共5页 Tool Engineering
基金 国家自然科学基金(31500587) 中央高校基本科研业务费专项资金(2572016CB10)
关键词 地面三维激光扫描仪 测距 水平角 精度 terrestrial laser scanner measurement distance horizontal angle accuracy
  • 相关文献

参考文献7

二级参考文献30

  • 1郑德华,沈云中,刘春.三维激光扫描仪及其测量误差影响因素分析[J].测绘工程,2005,14(2):32-34. 被引量:239
  • 2刘春,杨伟.三维激光扫描对构筑物的采集和空间建模[J].工程勘察,2006,34(4):49-53. 被引量:69
  • 3於宗俦 鲁林成.测量平差基础[M].北京:测绘出版社,1982..
  • 4於宗俦 鲁林成.测量平差基础[M].北京:测绘出版社,1983..
  • 5刘大杰.全球定位系统(GPS)的原理与数据处理[M].上海:同济大学出版社,1997.163-166.
  • 6王旭华.条件方程与误差方程系数矩阵之间的关系[J].矿山测量,1988,(2):20-23.
  • 7程光亮,张福利,王宝山.3维激光扫描技术在工程应用中的精度探讨[J].测绘与空间地理信息,2007,30(4):25-27. 被引量:16
  • 8周华伟.地面三维激光扫描点云数据处理与模型构建[D].昆明:昆明理工大学,2011.
  • 9刘春,张蕴灵,吴杭彬.地面三维激光扫描仪的检校与精度评估[J].工程勋察,2009(11):56-60.
  • 10POLO M, FELICISIMO A M, VILLANUEVA A G, et al. Estimating the Uncertainty of Terrestrial Laser Scanner Measurements[J]. IEEE Transactions on Geoscience and Remote Sensing,2012,50(11):4804-4808.