摘要
结合某民用建筑,根据我国现行标准规范的要求,探讨了民用建筑物防雷装置的设计,分析了低压配电系统电涌保护器(SPD)的选择等设计要点及注意事项。提出建筑电气设计人员应根据国家现行规范和实际工程要求,选择最合适的防雷保护设计方案。
Combining by a civil building project,the design of lightning protection device was discussed according to current standard specification requirements. The design points and matters needing attention were anayzed,such as surge protective device( SPD) selection of low voltage power distribution system. It is pointed out that according to the requirements of current standard specifications and actural engineering project,the design scheme the most suitable lightning protection is selected.
作者
潘虹
PAN Hong(Shanghai Urban Transportation Design Institute Co. , Ltd. , Shanghai 200025, Chin)
出处
《现代建筑电气》
2018年第3期33-36,共4页
Modern Architecture Electric
关键词
防雷设计
电涌保护器(SPD)
雷击电磁脉冲
消防监控中心
lightning protection design
surge protective device (SPD)
lightning electromagnetic pulse
fire control center