期刊文献+

二氧化氯发生器残液处理方法研究与比较 被引量:3

Comprehensive comparison of treating methods for residual liquid of chlorine dioxide generator
原文传递
导出
摘要 采用离子交换膜、离子交换树脂和铁粉还原法对复合法制备二氧化氯过程中产生的高浓度氯酸盐残液进行处理,对3种方法进行综合比较。结果表明:离子交换膜处理后氯酸盐富集质量浓度为13.06 g/L,为进水质量浓度的6.5倍,去除率大于50%,离子交换膜不可重复使用;离子交换树脂处理后富集质量浓度为23.51 g/L,为进水质量浓度的11.8倍,去除率为95%,离子交换树脂可重复使用;铁粉对氯酸根去除率为99%,可连续使用15次。综合比较处理效果、控制条件和处理成本,选择铁粉还原法为最佳方法。 The present paper intends to make a comparative study of the three methods to prepare high concentrated chlorate residue solution in the process of compound chlorine dioxide by taking chlorate as an oxygen-containing anion with strong oxidizing properties.For this need,it is recommended to use the ion exchange membrane,ion exchange resin and the iron powder reduction method.The ion exchange membrane reactor can be operated continuously and continually.When the initial mass concentration of sodium chloride in the exchange solution is 270 g/L,the reaction temperature should be taken as(25 ± 1) ℃,at the initial pH value of 7.0,with the stirring intensity being 200 r/min and the running time being 240 minutes.In such a condition,the enrichment mass concentration of chlorate can be 13.06 g/L,that is,6.5 times of the influent concentration and the removal rate of about 50%,though the ion exchange membrane fail to be repeatedly employed.The results of the dynamic experiment of the ion exchange resin indicate that the enrichment mass concentration rate of chlorate can be expected to reach 23.51 g/L,that is,11.8 times of the influent concentration at the removal rate of95%.In so doing,the following conditions should be satisfied:the residence time:19.6 min;the reaction temperature:(25 ± 1)℃;the initial pH value:7.0,and the lasting time:240 minutes.Otherwise,if the ion exchange resins wanted to be reused and the iron powder were to be used continuously for 15 times,the following conditions have to be satisfied:the initial pH value:2.0;the iron powder:10 g;the rotation speed:150 r/min;the reaction temperature:(25 ± 1) ℃.In such conditions,the removal rate of chlorate can be made as high as to 99%.And,so far as we know,the cost of ion exchange membrane:about 2.07 yuan/L;the ion exchange resin:0.17 yuan/L;and the iron powder reduction method:at about 0.10 yuan/L,respectively.And,so far as we know,the control condition of the iron powder reduction method can be expected the simplest one because it only needs to be added and mixed in with the equipment.Thus,as compared in treating effect,processing cost and the control condition,the iron powder reduction method can be chosen as the best one.
作者 董文艺 王安娜 吴桂楠 赵福祥 孙飞云 张冠 DONG Wen-yi;WANG An-na;WU Gui-nan;ZHAO Fu-xiang;SUN Fei-yun;ZHANG Guan(Shenzhen Key Laboratory of Water Resource Application and Environment Pollution Control, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, Guangdong, China)
出处 《安全与环境学报》 CAS CSCD 北大核心 2018年第2期678-683,共6页 Journal of Safety and Environment
基金 水体污染控制与治理科技重大专项(2015ZX07406-004)
关键词 环境工程学 二氧化氯发生器残液 氯酸盐 离子交换膜 离子交换树脂 铁粉 environmental engineering residue from chlorine dioxide generator chlorate ion exchange membrane ion exchange resin iron powder
  • 相关文献

参考文献2

二级参考文献33

  • 1韩艳淑,陈素良,甄素娟,郭逸秀.二氧化氯发生器对饮用水消毒效果观察[J].中国消毒学杂志,2005,22(1):43-45. 被引量:6
  • 2黄春,王蕾.北京市自来水中总有机碳监测及应用的研究[J].城镇供水,2005(4):31-34. 被引量:2
  • 3王晓蕾,徐燕.二氧化氯对水中细菌杀灭效果及影响因素的观察[J].中国消毒学杂志,2005,22(3):280-281. 被引量:6
  • 4.消毒技术规范[M].[S].中华人民共和国卫生部,2002.99.
  • 5KOMULAINEN H. Experimental cancer studies of chlorinated byproducts[J]. Toxicology, 2004,198(1-3) :239-248.
  • 6MICHAEL G E, MIDAY R K, BERCZ J P, et al. Chlorine dioxide water disinfection: a prospective epidemiology study [ J ]. Arch Environ Health, 1981,36 ( 1 ) : 20-27.
  • 7APHA. Standard methods for the examination of water and wastewater [ M ]. 20th ed. Washington DC : APHA, 1998:42-51.
  • 8KATZ A, NARKIS N, ORSHANSKY F, et al. Disinfection of effluent by combinations of equal doses of chlorine dioxide and chlorine added simultaneously over varying contact times [ J]. Water Res, 1994, 28 (10) : 2133-2138.
  • 9NARKIS N, KATZ A, ORSHANSKY F, et al. Disinfection of effluents by combinations of chlorine dioxide and chlorine[J]. Water Sci Technol, 1995, 31(5) : 105-114.
  • 10CHEN S S, LI C W, LEE P C. Concentration and purification of chromate from electroplating wastewater by two-stage electrodialysis processes[J] . Journal of Hazardous Materials, 2009, 161(2/3): 1075-1080.