期刊文献+

基于大开间理念的220kV全户内变电站布置方案优化 被引量:4

Optimization design of 220kV indoor substation based on merged distribution room
下载PDF
导出
摘要 本文针对常规220kV变电站占地面积和建筑面积大的问题,研究了220kV全户内变电站优化设计方案。提出"大开间"模块化设计理念,将各级配电装置、二次屏柜等进行模块化设计、组合拼接,同层共室布置,共享运维检修通道,减小建筑面积。采取固定式吊装、耐压试验套管横向布置等措施,有效降低建筑层高。经优化,全站总建筑面积和围墙内占地面积较南方电网标准设计方案分别减少81.4%和38.3%。 Concerned of the large occupied area and building area of 220kV substation, the paper is focused on optimization design of 220kV indoor substation. Merged distribution room is applied, in which switchgear of different voltage levels and secondary panels are modular designed and arranged. Room clear height is declined by the fixed-up lifting method and horizontal arrangement of testing bushing. Compared with standard design, the optimization scheme has the advantages of saving 81.4% building area and 38.3% occupied area.
作者 羌丁建 李海烽 熊静 陈斌 Qiang Dingjian;Li Haifeng;Xiong Jing;Chen Bin(China Energy Engineering Group Jiangsu Power Design Institute Co., Ltd, Nanjing 210000)
出处 《电气技术》 2018年第4期77-82,共6页 Electrical Engineering
关键词 变电站 平面布置 优化设计 大开间 substation plan layout optimization design merged distribution room
  • 相关文献

参考文献10

二级参考文献43

  • 1严薇,曹永红,李国荣.装配式结构体系的发展与建筑工业化[J].重庆建筑大学学报,2004,26(5):131-136. 被引量:172
  • 2包红旗,郗晓光.HGIS组合电器的技术特点[J].天津电力技术,2006(2):40-42. 被引量:10
  • 3M. J. Nigel Priestley. Overview of PRESSS Research Program[J]. PCI Journal.36(4),July-August 1991,50-57.
  • 4Jubum Kim.Behavior of Hybrid Frame Under Seismic Loading[D], dissertation of Civil & Environmental Engineering, University of Washington.2002.
  • 5DL/T 5056-2007,变电站总布置设计技术规程[S].
  • 6DL/T5352-2006高压配电装置设计技术规程[S].北京:中国电力出版社,2007.
  • 7GB50017-2003.钢结构设计规范[S].[S].,2003..
  • 8罗学琛.SR^6气体绝缘全封闭组合电器(GIS)[M].北京:中国电力出版社,2007:83-101.
  • 9DL/T617-2010气体绝缘金属封闭开关设备技术条件[S].北京:中国电力出版社,2010.
  • 10包红旗.HGIS与数字化变电站[M].北京:中国电力出版社,2007:1-11.