摘要 覆盖气净化系统失效事件是2 MW液态燃料钍基熔盐实验堆(Thorium Molten Salt experimental ReactorLiquid Fueled,TMSR-LF1)可能导致放射性释放的典型假想事件之一。本文根据事件的释放模式和源项,在保守假设的情况下,使用ARCON96计算事件发生后厂房各边界处的大气弥散因子,估算事件发生后假设的烟囱下风向各厂房边界处的工作人员的个人有效剂量,然后分析事件发生后反应堆厂房内的可居留性。经过计算可以得出,覆盖气净化系统失效事件发生后,产生的有效剂量主要来源于浸没外照射途径。厂房边界处最大24 h全身累积剂量为3.04 mSv,低于国家核安全导则规定的场区应急行动水平,事件发生后TMSR-LF1将进入厂房应急状态,无需场外应急。 [Background] The cover gas purge system failure incident is one of the typical incidents of 2 MW liquid-fueled thorium molten salt experimental reactor - liquid fueled (TMSR-LF1), which could result in radiation releasing. [Purpose] This paper attempts to analyze the habitability for operations in the powerhouse under the cover gas removal system failure incidental condition, and provide data for nuclear emergency for TMSR-LF1. [Methods] Based on source items and emission pattern, we did conservative evaluations of atmospheric dispersion factors of powerhouse boundaries by using ARCON96 and 24 h individual effective dose for occupational workers locate at powerhouse boundaries. [Results] For this incident, the highest 24 h individual cumulative dose is 3.04 mSv and it appears on the powerhouse boundary nearest to the reactor core. [Conclusion] Compared the results with the national standards, it is not up to site-area emergency action level so that the reactor would enter in alert emergency classification,
作者 陈畅其 夏晓彬 蔡军 张志宏 李长园 CHEN Changqi;XIA Xiaobin;CAI Jun;ZHANG Zhihong;LI Changyuan(Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Jiading Campus, Shanghai 201800, China) 2(University of Chinese Academy of Sciences, Beijing 100049, China)
出处 《核技术》 CAS CSCD 北大核心 2018年第5期89-94,共6页 Nuclear Techniques
基金 中国科学院战略性先导科技专项(No.XDA02005004)资助~~
关键词 液态燃料钍基熔盐实验堆 覆盖气净化系统失效 有效剂量 应急行动水平 TMSR-LF1, The cover gas purge system failure, Effective dose, Emergency action level
  • 相关文献

参考文献2

二级参考文献17

  • 1Murphy K, Campe K. Nuclear power plant control room ventilation system design for meeting general criterion 19[C]//Proceedings of 13th AEC Air Clean ing Conference. 1974.
  • 2Ramsdell J. NUREG/CR-5055 Atmospheric diffusionfor control room habitability assessments[R]. Pacific N orthwest Lab, Richland, WA (USA) , 1988.
  • 3Ramsdell Jr J. Diffusion in building wakes for ground-level releases[J]. Atmospheric Environment Part B Urban Atmosphere, 1990, 24 (3): 377-388.
  • 4Ramsdell Jr J, Simonen C, Smyth S. Atmospheric rela- tive concentrations in building wakes. Nuclear Regu- latory Commission[R]. Washington. DC (United States). Div. of Radiation Safety and Safeguards; Pacific Northwest Lab. Richland, WA (United States) , 1995.
  • 5USNRC. Standard review plan for the review of safety analysis reports for Nuclear Power Plants[S]. Chapter 6.4 " Control Room Habitability System" . 1987.
  • 6USNRC. Regulatory Guide 1.194 Atmospheric rela- tive concentrations for control room radiological habitability assessments at nuclear power plants[S]. 2003.
  • 7Ramsdell Jr J, Fosmire C. Atmospheric dispersion estimates in the vicinity of buildings[R~ Pacific North- westLab, Richland, WA (United States) , 1995.
  • 8MURPHY K, CAMPE K. Nuclear power plant control room ventilation system design for meeting general criterion 19[C] ffProceedings of 13th AEC Air Cleaning Conference. San Francisco, California, U. S:. Atomic Energy Commission, 1974(1) : 401-430.
  • 9RAMSDELL J V. Atmospheric diffusion for control room habitability assessments, Report NUREG/CR-5055[R]. Washington, U. S. Nu- clear Regulatory Commission, 1988.
  • 10RAMSDELL J V. Diffusion in building wakes for ground-level releases[J]. Atmospheric Envi- ronment B, 1990, 24(3): 377-388.