摘要 目前电能表掉零线误差校准和检验普遍采用光电或有线方式读电能表的脉冲得到误差,并同步实现误差的校准和检验的方法。探讨一种把电能表、智能台体和上位机制程软件三者高效配合起来校准和检验掉零线误差的方法,从而实现高效快速地掉零线误差校准和检验。 The current energy meter out of the zero line error calibration and inspection commonly used optical or wired way to read the energy meter to get the error,and synchronously achieved the error calibration and testing methods. In this paper,we explore a method of the zero line error calibration and verification by integrating the energy meter,intelligent platform and the host computer process software so as to achieve efficient and fast zero line error calibration and testing.
作者 徐京生 纪明佳 梁万磊 董占国 梁志强 XU Jing-sheng1 , JI Ming-jia2, LIANG Wan-lei3, DONG Zhan-guo1 , LIANG Zhi-qiang1(1. Holley Technology Ltd, Hangzhou 310023, China; 2. State Grid Jilin Power Co. ,Ltd, Baicheng Power Company, Jilin 137099, China; 3. State Grid Neimenggu East Electric Power Co. , Ltd, Erguna City Power Branch, Erguna 022250, Chin)
出处 《仪表技术》 2018年第5期30-33,共4页 Instrumentation Technology
关键词 电能表 掉零线误差 校准系统 energy meter zero line error calibration system