期刊文献+

装配整体式混凝土双肢剪力墙受力性能非线性有限元分析 被引量:4

Nonlinear Finite Element Analysis of Monolithic Precast Concrete Coupled Shear Wall
下载PDF
导出
摘要 双肢剪力墙是装配整体式混凝土剪力墙体系中较为常见的墙体形式。基于ABAQUS软件,建立了考虑材料非线性和预制拼缝构造等因素影响的装配整体式混凝土双肢剪力墙非线性有限元分析模型。通过与试验结果的对比分析,验证了该有限元分析模型的合理性。在此基础上,开展了装配整体式混凝土双肢剪力墙的有限元参数分析,主要分析参数包括轴压比、连梁跨高比等。结果表明:高轴压比(0.5)试件的承载力比低轴压比(0.2)试件高约24%,而不同轴压比试件的刚度相差在5%以内;相比于连梁跨高比为3的试件,连梁跨高比为2和2.5的试件承载力分别提高了7.5%和19.4%,刚度分别提高了19.2%和41.2%。 Coupled shear wall is a common form in the monolithic precast concrete shear wall structure.Based on ABAQUS software,considering the material nonlinearity and the structure of the monolithic precast concrete flat-fell seam,a finite element model of the precast concrete coupled shear wall was established. Based on the test results of a coupled wall specimen,the verification of the finite element analysis model was carried out. And based on the model,analysis of the factors including compression ratio and the span-depth ratio of the coupled shear wall was carried out. The results showed the fact that the bearing capacity of specimen under high axial compression ratio( 0. 5) was about 24% higher than that of the specimen under low-axial compression ratio( 0. 2),while the stiffness difference of the specimens under different compression ratio was less than 5%. Compared with the specimen with a 3 span-depth ratio coupling beam,the bearing capacity of the specimens with 2 and 2. 5 span-depth ratio coupling beam increased by 7. 5% and 19. 4% respectively,and the stiffness increased by 19. 2% and41. 2% respectively.
作者 李昌州 秦端 胡翔 薛伟辰 LI Changzhou;QIN Duan;HU Xiang;XUE Weichen(China Minsheng Orawin Co. , Ltd. , Changsha, Hu' nan 410000, China;Department of Structural Engineering, Tongji University, Shanghai 200092, China)
出处 《施工技术》 CAS 2018年第12期35-38,47,共5页 Construction Technology
基金 国家重点研发计划项目(2016YFC0701400) 上海市科委项目(16DZ1201802)
关键词 剪力墙 装配整体式混凝土 双肢剪力墙 轴压比 连梁跨高比 有限元分析 shear wails monolithic precast concrete coupled shear wails compression ration coupling beam span-depth ratio finite element analysis
  • 相关文献

参考文献7

二级参考文献47

  • 1刘伟庆,江东,丁大钧.钢筋砼裂缝截面剪力传递性能的试验研究[J].建筑结构学报,1994,15(4):2-10. 被引量:9
  • 2种迅,孟少平,潘其健,张林振.预制预应力混凝土框架结构形式及设计方法研究[J].工业建筑,2006,36(5):5-8. 被引量:14
  • 3徐有邻.介绍几种预制构件新产品[J].混凝土,1996(5):4-9. 被引量:5
  • 4JGJl01-96建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997.
  • 5SHEN Q, KURAMA Y. Lateral load behavior of nn- bonded post-tensioned hybrid coupled walls [ C]//Sixth ASCCS Conference on Steel and Concrete Composite Structures. Los Angeles : [ s. n. ], 2000,22/23/24 : 793 - 800.
  • 6KURAMA Y, SAUSE R, PESSIKI S, et al. Seismic re- sponse evaluation of unbonded post-tensioned precast walls [J]. ACI Struct J,2002, 99(5) : 641 -651.
  • 7SHEN Q, KURAMAY. Nonlinear behavior of post-ten- sioned hybrid coupled wall subassemblages [ J]. Journal of Structural Engineering, American Society of Civil En- gineers, 2002, 128 (10) : 1290 - 1300.
  • 8KURAMA Y, SHEN Q. Post-Tensioned hybrid coupled walls under lateral loads [ J ]. Journal of Structural En- gineering, American Society of Civil Engineers, 2004, 130(2) :297 - 309.
  • 9SHEN Q, KURAMAY, WELDON B. Seismic design and analytical modeling of post-tensioned hybrid coupled wall suhassemhlages [ J]. Struct Eng, 2006, 132 (7) : 1030 - 1040.
  • 10Steph Pessiki, Richard Prior, Richard Sause and Sarah Slaughter. Review of Existing Precast Concrete Gravity Load Floor-framing Systems.PCI Journal, 1995(2) :52 ~ 68

共引文献99

同被引文献30

引证文献4

二级引证文献12