期刊文献+

商品纳氏试剂在地表水氨氮分析中的应用 被引量:5

Application of Commercial Nessler Reagent in Ammonia Nitrogen Determination for Surface Water
下载PDF
导出
摘要 考察3种商品纳氏试剂在地表水氨氮分析中的适用性。研究了纳氏试剂在不同显色时间和加入量下的使用效果,得出3种商品纳氏试剂的最佳使用条件。通过检出限试验、实际地表水样测定以及加标回收试验对商品纳氏试剂进一步筛选,确定了适合地表水氨氮分析的纳氏试剂,并为商品纳氏试剂的可靠性提供了可行的检验方法。 The applicability of ammonia nitrogen determination in surface water by 3 commercial Nessler reagents was evaluated.The using effect of Nessler reagent under different chromogenic times and dosages was investigated,and the optimum working conditions of 3 commercial Nessler reagents were obtained.The detection limit test,determination of actual surface water and recovery test were applied for the further selection of commercial Nessler reagents.The most suitable Nessler reagent for ammonia nitrogen determination in surface water was ascertained,and the feasible test method for the reliability of commercial Nessler reagent was also provided.
作者 王炜 陈晶 廖爱仙 章佳 WANG Wei;CHEN Jing;LIAO Ai-xian;ZHANG Jia(Zhejiang Environmental Monitoring Engineering Co., Ltd., Hangzhou 310012, China)
出处 《化学试剂》 CAS 北大核心 2018年第7期663-666,共4页 Chemical Reagents
关键词 商品纳氏试剂 地表水 氨氮 适用性 commercial Nessler reagents surface water ammonia nitrogen applicability
  • 相关文献

参考文献14

二级参考文献131

共引文献161

同被引文献41

引证文献5

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部