摘要 针对现有伽玛射线剂量(率)测量仪器检定方法送检距离远、周期长、效率低的不足,中国工程物理研究院核物理与化学研究所采用基于样本仪表的机器预测方法,开展了基于小尺度参考辐射的便携式伽玛剂量(率)仪遂行校准技术研究工作。最终成功地研制了一套辐射防护用伽玛射线剂量(率)仪遂行校准装置,实现了测量标准不确定度不大于5%的良好结果。为伽玛空气比释动能量值的遂行定度提出了一条全新的技术思路,为便携式伽玛剂量(率)仪的现场和野外校准提供了一种全新的示范装备。 The existing calibration methods of gamma ray dose (rate) meters have the disadvantages of long distance, long period and low efficiency. To overcome these disadvantages, the Instituteof Nuclear Physics and Chemistry of the Chinese Acade my of Engineering Physics applies a machine learning prediction method using sample instruments to carry out a research on field calibration technology for portable gammadose (rate) meters based on minitype reference radiation. A field calibration device for gamma dose (rate) meters for radiation protection was successfully developed, which achieved a satisfactory result with a meas urement standard uncertainty of no more than 5Y0. This paper also presents a new method for determination of the conventional true value of gamma ray air kerma, and provides a novel model equipment for field calibration of the portable gamma dose (rate) meters.
作者 钱易坤 魏彪 刘易鑫 李文杰 毛本将 冯鹏 Qian Yikun;Wei Biao;Liu Yixin;Li Wenjie;Mao Benjiang;Feng Peng(Key Laboratory of Opto electronics Technology & System of Ministry of Education Chongqing University,Chongqing 400044,China;Institute of Nuclear Physics and Chemistry,CAEP,Mianyang 621999,China;Department of Engineering Physics,Tsinghua University,Beijing 100081,China)
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2018年第9期147-153,共7页 High Power Laser and Particle Beams
基金 国防科工局研究课题 重庆大学中央高校基本科研业务费资助项目(2018CDGFGD0008)
关键词 伽玛空气比释动能 小尺度参考辐射 遂行校准技术 辐射防护 gamma ray air kerma minitype reference radiation field calibration technology radiation protection
  • 相关文献

参考文献6

二级参考文献29

  • 1史东生,弟宇鸣,周春林.小波变换与傅立叶变换在γ能谱降噪处理中的比较研究[J].核电子学与探测技术,2007,27(1):134-137. 被引量:13
  • 2于水,王功鹏,关守任.低大气层宇宙射线剂量水平及机组人员受照剂量的研究[J].辐射防护,1997,17(2):103-108. 被引量:7
  • 3岳清宇,金花.低大气层中宇宙射线电离量的分布测量[J].辐射防护,1988,8(6):401-409.
  • 4Health and Sa{ety Laboratory. High pressure ar- gon ionization chamber systems for the measure- ment of environmental radiation exposure rates [R]. New York: HASL260, 1972.
  • 5任天山,林莲卿,陈志鹏.宇宙射线电离量的测定和几种探测器对宇宙射线的响应[J].辐射防护,1987,7(3):185-190.
  • 6International Organization for Standardization. X and gamma reference radiations for calibrating dose- meters and dose rate meters and for determining their response as a function of photon energy, Part 1: Radiation characteristics and production method [S]. Geneva: ISO Publication Office, 1997.
  • 7全国核能标准化技术委员会.GB/T12162.1-2000用于校准剂量仪和剂量率仪及确定其能量响应的x和Y参考辐射,第一部分:辐射特性及产生方法[s].北京:中国标准出版社,2000.
  • 8de PLANQUE G, GESELL T F. Environmental measurements with thermoluminescence doseme- ters-trends and issues[J]. Radiation Protection Dosimetry, 1986, 17: 193-200.
  • 9MAIELLO M L G. 8'h international intercompar- ison of environmental dosemeters[J]. Radiation Protection Dosimetry, 1990, 32: 91-98.
  • 10MAIELLO M L G. Ninth international 'mini' intereomparison of environmental dosemeters: A further analysis of the data[J], Radiation Protec- tion Dosimetry, 1995, 58: 167-175.

共引文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部