期刊文献+

浅谈HJ 836-2017《固定污染源废气低浓度颗粒物的测定 重量法》 被引量:6

Interpretation of HJ 836-2017 <Stationary Source Emission-Determination of Mass Concentration of Particulate Matter at Low Concentration-Manual Gravimetric Method>
下载PDF
导出
摘要 对《固定污染源废气低浓度颗粒物的测定重量法》(HJ 836-2017)的适用范围、检出限、技术路线(采样前准备、现场采样要求和采样后样品称量计算)及质量控制等进行了解读。标准适用于排放浓度不大于50 mg/m^3的颗粒物检测;方法检出限为1 mg/m^3;通过改进采样头、增加采样设备预热功能、整体称量的方式等手段,减少采样及称重过程引入的误差;增加全程序空白及同步双样的质控要求保证检测过程的准确性。 The scope of application, detection limit, technical route (pre-sampling preparation, field sampling requirements and post-sampling sample weighing calculation) and quality control of 〈Stationary source emission-Determination of mass concentration of particulate matter at low concentration-Manual gravimetric method〉 (HJ 836-2017) has been interpreted. The standard applies to the detection of particle concentrations of no more than 50 mg/m3. The detection limit of the method is 1 mg/m3. To avoid the inaccuracies in the process of sampling and weighing by improving sampling, increasing preheat function of sampling equipment and using the overall weighing method. The quality control requirements of overall blank and paired train sample can guarantee the accuracy of the detection process.
作者 罗海恩 李娜 朱佳焘 郑国华 LUO Hai-en;LI Na;ZHU Jia-tao;Zheng Guo-hua(Guangzhou Zhongke Testing Service Co.,Ltd.,Guangzhou 510650,China)
出处 《广州化学》 CAS 2018年第3期70-73,共4页 Guangzhou Chemistry
基金 珠江科技新星专项(201506010082)
关键词 低浓度颗粒物 固定污染源 重量法 采样方法 particulate matter at low concentration stationary source emission manual gravimetric method sample method
  • 相关文献

参考文献3

二级参考文献4

共引文献4

同被引文献20

引证文献6

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部