摘要
我国南方大多数沿海城市无论冬季还是夏季空气中普遍含湿量都较大,这些地方对空调机组的即有温度的要求还对除湿量要求较高。实验研究的新型冷凝热回收式恒温恒湿机组研发要求是它既可以很好地满足南方以及沿海城市除湿量的要求,又具有很好的节能效果,迎合现有的市场和社会需要。所研究的空调机组实验设备是基于上海某科技公司制造的新型冷凝热回收式恒温恒湿机组样机,研究主要内容包括:对变风量恒温恒湿空调机组的实验系统设计和机组在稳态工况情况下的特性测试及其结果。
Most of the coastal cities in South China, whether in winter or in summer, generally moisture content is higher in the air. In these places, the air - conditioning unit is not only the temperature requirements, but also the amount of dehumidification requirements. The research and development of new condensing heat recovery type constant temperature and humidity unit requires it not only can well meet the South and coastal city of dehumidification requirements', but also has a good energy saving effect, to cater to the existing market and social needs. The experimental unit of air conditioning unit studiedis a new condensing heat recovery type constant temperature and humidity unit prototype based on a corporation in Shanghai. The paper includes the design of experimental system for variable air volume constant temperature and humidity air conditioning unit and characteristic test of unit under steady condition and its' result.
作者
郭俊
翁文兵
李闻龙
GUO Jun;WENG Wen-bing;LI Wen-long(University of Shanghai for Science and Technology,Shanghai 200093,China)
出处
《建筑节能》
CAS
2018年第8期113-117,共5页
BUILDING ENERGY EFFICIENCY
关键词
恒温恒湿
空调机组
换热量
热湿特性
constant temperature and humidity
air conditioning units
heat transfer
hot and humid characteristics