摘要
结合某电厂300 MW机组6台高压加热器给水温度低于设计值的异常情况,分析认为分水隔板冲刷、隔板垫片损坏导致的水侧短路是给水温升偏低的主要原因,提出优化分水隔板材质、结构和法兰结构等高压加热器水室分水隔板的改造措施,通过运行情况说明改造效果。
According to the abnormal phenomenons of temperature-rise decreasing of six high pressure heaters of 300 MW turbine in some power plant,this paper proves that the prime reason is short-circuit of water side of high pressure heater through analysis,proposes methods by optimizing the materials and structures of chamber clapboard and manhole flange of high pressure heater,illustrates the effect of revamp by running conditions.
作者
田志强
TIAN ZhiQiang(Matou Cogeneration Branch Company of Datang Hebei Power Generation Co.Ltd.,Handan 056044,China)
出处
《河北电力技术》
2018年第4期40-41,54,共3页
Hebei Electric Power
关键词
高压加热器
给水温升
水侧短路
水室
分水隔板
人孔
high pressure heater
temperature-rise of power supply
water side short-circuit
water chamber
clapboard
manhole