期刊文献+

磁共振扩散加权成像技术的应用进展 被引量:2

Application Process of Magnetic Resonance Imaging Diffusion-weighted MR Imaging Technology
下载PDF
导出
摘要 磁共振扩散加权成像(DWI)可以检出常规磁共振成像不能发现的病灶,最初主要应用于中枢神经系统,随着磁共振硬软件的发展,其应用范围可扩大到全身各组织器官。该研究拟从DWI的技术进展和临床应用两方面概述DWI技术的应用进展。 The DWI can test the lesions that the routine MRI can not discover, it is mainly used in the central nervous system initially, but with the development of MRI software and hardwafe, the application range can be expanded into various organs and tissues in the whole body. The paper plans to summarize the application process of DWI technology from the technological process and clinical application of DWI.
作者 魏祖生 WEI Zu-sheng(Department of Medical Imaging,Guangxi Zhuang Autonomous Region Nanxi Mountain hospital,Guilin,Guangxi,541002 China)
出处 《系统医学》 2018年第13期190-192,共3页 Systems Medicine
关键词 磁共振成像 扩散加权成像 临床应用 进展 Magnetic resonance imaging Diffusion-weighted imaging Clinical application Process
  • 相关文献

参考文献18

二级参考文献114

  • 1陈首名,李光纪,罗鹰,何志兵,马方伟,左斌.病毒性脑炎常规磁共振及弥散加权成像表现分析[J].吉林医学,2013,34(13):2424-2426. 被引量:5
  • 2张世魁,马娅琼,杨蓉佳,曲强,李永胜.128层螺旋CT灌注成像在诊断急性脑梗死及评价患者临床预后的应用价值[J].中国动脉硬化杂志,2015,23(6):603-606. 被引量:27
  • 3Le Bihan D, Breton E, Lallemand D, et aL MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders[J]. Radiology, 1986, 161(2): 401-407.
  • 4Zhang JL, Sigmund EE, Chandarana H, et al. Variability of renal apparent diffusion coefficients: limitations of the monoexponential model for diffusion Radiology, 2010, 254(3):783-792.
  • 5Le Bihan D, Breton E, Lallemand D, et al. Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging[J]. Radiology, 1988, 168(2):497-505.
  • 6Le Bihan D, Turner R. The capillary network: a link between IVIM and classical perfusion[J]. Magn Reson Med, 1992, 27 (1):171-178.
  • 7Lemke A, Stiehjes B, Schad LR, et al. Toward an optimal distribution of b values for intravoxel incoherent motion imaging[J]. Magn Reson Imaging, 2011, 29(6):766-776.
  • 8Zhang JL, Sigmund EE, Rusinek H, et al. Optimization of b-value sampling for diffusion-weighted imaging of the kidney [J]. Magn Reson Med, 2012, 67(1):89-97.
  • 9Koh DM, Collins D J, Orton MR. Intravoxel incoherent motion in body diffusion-weighted MRI: reality and challenges[J]. AJR Am J Roentgenol, 2011,196(6):1351-1361.
  • 10Chou SY, Porush JG, Faubert PF. Renal medullary circulation: hormonal control[J]. Kidney Int, 1990, 37(1):1-13.