摘要 目的分析双源CT冠脉造影和SPECT对评估心肌灌注异常与冠脉狭窄的相关性。方法筛选出36例拟诊或确诊的冠心病患者作为研究对象,对其行双源CT冠脉造影和SPECT心肌灌注显像,分析影像学检查结果,评价心肌灌注异常与冠脉狭窄的相关性。结果双源CT冠脉造影检查可评价的冠脉血管节段共446段,诊断为冠脉正常21例(403段),狭窄13例(40段),闭塞2例(3段)。SPECT心肌灌注显像检查,可评价的心肌节段共601段,诊断为心肌灌注正常27例(580段),心肌灌注异常9例(21段)。以SPECT心肌灌注显像为金标准,双源CT冠脉造影检出冠脉狭窄为50%时,检出心肌灌注异常的准确率、敏感性、特异度、阳性预测值、阴性预测值依次为85%、78%、87%、71%、91%。结论双源CT冠脉造影和SPECT心肌灌注显像诊断冠心病的应用价值高,对评估心肌灌注异常与冠脉狭窄的相关性具有非常重要的指导意义。 Objective To analyze the correlation between dual source CT coronary angiography and SPECT in evaluating myocardial perfusion abnormalities and coronary stenosis. Methods 36 patients with coronary heart disease were selected as the subjects. The two source CT coronary angiography and SPECT myocardial perfusion imaging were performed. The results of imaging examination were analyzed,and the correlation between myocardial perfusion abnormality and coronary stenosis was evaluated. Results A total of 446 segments of coronary artery segments were evaluated by dual source CT coronary angiography,and 21 cases( 403 segments) were diagnosed as normal coronary artery,13 cases( 40 segments) and 2 occlusion( 3 segments). A total of 601 segments of cardiac muscle segment were evaluated by SPECT myocardial perfusion imaging. 27 cases( 580 segments) were diagnosed as normal myocardial perfusion and 9 cases( 21 segments) were abnormal myocardial perfusion. With SPECT myocardial perfusion imaging as the gold standard,the accuracy,sensitivity,specificity,positive predictive value and negative predictive value of myocardial perfusion abnormalities were 85%,78%,87%,71% and 91% in the case of 50% coronary stenosis detected by dual source CT coronary angiography. Conclusions The dual source CT coronary angiography and SPECT myocardial perfusion imaging are of high value in the diagnosis of coronary heart disease. It is of great guiding significance for the evaluation of the correlation between abnormal myocardial perfusion and coronary stenosis.
作者 刘高炳 LIU Gaobing(Department of Radiology,First Affiliated Hospital,Uni-versity of South China,Hengyang 421001,China)
出处 《航空航天医学杂志》 2018年第9期1047-1049,共3页 Journal of Aerospace medicine
关键词 双源CT冠脉造影 SPECT 心肌灌注异常 冠脉狭窄 相关性 dual source CT coronary angiography SPECT myocardial perfusion abnormalities coronary stenosis correlation
  • 相关文献

参考文献10

二级参考文献38

  • 1马东星,刘惠亮,吴晓霞,姚宏英,赵旭燕,张耀芬,陈燕,蒲朝煜.腺苷负荷心肌灌注显像在老年冠心病患者诊断中的价值[J].心肺血管病杂志,2010,29(S1):73-74. 被引量:7
  • 2苗翠莲,张兆琪,郭曦,徐超,王珏,米宏志.负荷MR心肌灌注成像检测冠心病心肌缺血与冠状动脉造影及^(99m)Tc-SPECT对比的初步研究[J].中国CT和MRI杂志,2005,3(4):21-24. 被引量:4
  • 3无.慢性稳定性心绞痛诊断与治疗指南[J].中华心血管病杂志,2007,35(3):195-206. 被引量:2079
  • 4Gaemperli O,Schepis T,Kalff V,et al.Validation of new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography.Eur J Nucl Med Mol Imag,2007,34:1097-1106.
  • 5Mowatt G,Vale L,Brazzelli M.Systematic review of the effectiveness and cost-effectiveness,and economic evaluation,of myocardial perfusion scintigraphy for the diagnosis and management of angina and myocardial infarction.Health Technol Assess,2004,8:1-207.
  • 6Schwitter J,Wacker CM,Wilke N,et al.MR-IMPACT II:magnetic resonance imaging for myocardial perfusion assessment in coronary artery disease trial:perfusion-cardiac magnetic resonance vs.single-photon emission computed tomography for the detection of coronary artery disease:a comparative multicentre,multivendor trial.Eur Heart,2013,34:775-781.
  • 7Greenwood JP,Maredia N,Younger JF,et al.Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease(CE-MARC):a prospective trial.Lancet,2012,379:453-460.
  • 8Schwitter J,Wacker CM,Van Rossum AC,et al.MR-IMPACT:comparison of perfusion-cardiac magnetic resonance with singlephoton emission computed tomography for the detection of coronary artery disease in a multicentre,multivendor,randomized trial.Eur Heart J,2013,29:480-489.
  • 9Wolk MJ,Bailey SR,Doherty JU,et al.American college of cardiology foundati on appropriate use criteria task force ACCF/AHA/ASE/ASNC/HFSA/HRS/SCAI/SCCT/SCM R/STS2013 multimodality appropriate use criteria for the detection and risk assessment of stable ischemic heart disease.J Am Coll Cardiol,2014,63:380-406.
  • 10Chen L,Wang X,Bao J,et al.Direct comparison of cardiovascular magnetic reso nance and single-photon emission computed tomography for detection of coronary artery disease:a meta-analysis.PLo S One,2014,9:e88402.