摘要
随着变电站自动化技术的不断发展,并行冗余协议已在国内得到部分应用,但还没有相对统一的测试方案。为了测试并行冗余协议的可靠性和实时性,并结合IEC 61850GOOSE规约,提出了一个系统化的并行冗余协议测试方案,并详细介绍了并行冗余协议的测试方法,为国内并行冗余协议的测试作为参考。
With the continuous development of substation automation technology, parallel redundant protocol (PRP) has been applied in some parts in China, but there is no relatively unified test scheme. In order to test the reliability and real-time of PRP, combining with IEC61850 GOOSE, this paper proposes a systematic PRP test scheme. The test method is introduced in detail, aiming to provide a reference for PRP test in China.
作者
师康
谷传国
朱春红
朱来强
SHI Kang, GU Chuanguo, ZHU Chunhong, ZHU Laiqiang(Siemens Power Automation Co. , Ltd. , Nanjing 211100, China)
出处
《电力与能源》
2018年第5期624-628,共5页
Power & Energy
关键词
并行冗余协议
GOOSE
智能变电站
parallel redundancy protocol (PRP)
GOOSE
intelligent substation