摘要
对6 kV高压异步电机软起动硬件进行设计,包括主电路和控制电路的设计,通过晶闸管的选取以及对晶闸管均压电路、触发系统、保护电路、信号采集电路、电源电路等设计,完成6 kV高压异步电机的软起动要求,为系统设计提供硬件基础。
The hardware and software of 6 kV high-voltage asynchronous motor are designed, including the design ofmain circuit and control circuit. Through the selection of thyristor and the design of thyristor equalizing circuit, triggersystem, protection circuit, signal acquisition circuit and power supply circuit, the soft starting requirement of 6 kV highvoltage asynchronous motor is completed, providing hardware basis for system design.
作者
韩蕾
Han Lei(Shanxi Fenxi Mining Group Mining Equipment Management Center,Jiexiu Shanxi03200)
出处
《山西冶金》
CAS
2018年第5期72-75,共4页
Shanxi Metallurgy
关键词
异步电机
软启动
硬件设计
asynchronous motor
soft start
hardware design