期刊文献+

低温空气源热泵与建筑室外机流动分析 被引量:1

Flow Analysis of Low-temperature Air Source Heat Pump and Outdoor Unit
下载PDF
导出
摘要 低温空气源热泵在北方农村供暖工程中有着重要的应用,本文主要针对空气源热泵室外机(V型翅片管换热器)的流场进行分析,讨论有风和无风状况下,室外机外侧的流场以及室外机对相邻机器的影响,为室外机优化设计提供一定的参考。。 The low-temperature air source heat pump has important applications in the rural heating project in the North. This paper mainly analyzes the fow feld of the outdoor unit (V-type fnned tube heat exchanger) of air-source heat pump. By discussing the fow feld outside of the outdoor unit and the infuence of the outdoor unit on adjacent machines under both the windy and windless conditions, it provides a certain reference for the optimal design of the outdoor unit.
作者 焦敏 许吉凯 张海静 魏晓蔚 靳印涵 鞠文杰 李先栋 Jiao Min;Xu Jikai;Zhang Haijing;Wei Xiaowei;Jin Yinhan;Ju Wenjie;Li Xiandong(Liaocheng Power Supply Company of Shandong Electric Power Company of State Grid,Liaocheng 252000,Shandong;Shandong Electric Power Company of State Grid,Jinan 250000,Shandong;Shandong Comprehensive Energy Service Co.,Ltd.of State Grid,Jinan 250000,Shandong)
出处 《建设科技》 2018年第22期86-89,共4页 Construction Science and Technology
基金 国网山东省电力公司科技项目资金资助
关键词 空气源热泵 供暖 数值模拟 Air source heat pump heating numerical simulation