期刊文献+

弹性支撑式高精度凝血动态检测传感器

High Precision Blood Coagulation Dynamic Detection Sensor Based on Spring Support
下载PDF
导出
摘要 随着对临床手术、免疫疾病、心血管疾病等科室患者血液凝固情况床旁快速检测(POCT,Point of Care Testing)的需求越来越大,凝血快速检测技术及方法引起学者及商业的广泛关注。本文提出一种以圆形片状弹簧作为弹性支撑的电磁感应凝血过程检测传感器。采用有限元法对弹性支撑进行模态分析与谐响应分析,优化分析结果并制作传感器试验样机,对传感器样机的速度及位移频谱特性进行了试验测试;搭建凝血测试装置,建立POCT快速检测血凝的标准曲线,与进口POCT凝血仪进行测试结果比对。结果表明,设计的传感器振动速度1.5μm/s,振幅1.75×10-3μm,其与进口POCT凝血仪测试结果相关性达到0.996,重复性达到0.002。通过该研究,为凝血检测提供电磁振动传感技术理论和实验基础。 With the increasing need for patients undergoing surgery, with immunological disease and cardiovascular dis ease, rapid detection techniques and methods of blood coagulation have caused wide attention in academia and the business community. This study had proposed a novel electromagnetic type coagulation detector with the round and leaf spring as the middle spring support, with dynamic testing sensor technology of coagulation in vitro as the research ob jective. Modal analysis and harmonic response analysis were conducted on the spring support group using finite element method, the analysis results were optimized, the sensor experimental prototype was manufactured, and the coagulation testing device was constructed. The velocity spectral characteristics and displacement spectral characteristics of the sensor prototype were tested, the standard curve of POCT in the rapid detection of coagulation was established through matching the coagulation testing device with coagulation reagent, and methodological comparison was performed with the im ported POCT coagulometer system. The vibration velocity of the sensor designed in this s study was 1.5μm/s, and the amplitude was 1.75×10 -3μm. Meanwhile, the correlation with the imported POCT coagulometer system in terms of test results was as high as 0.996, and the repeatability was 0.002. The study could provide theory and experimental foundation for the electromagnetic vibration induction technology in coagulation detection.
作者 王哲 于源华 陈启梦 李健 张震 WANG Zhe;YU Yuanhua;CHEN Qimeng;LI Jian;ZHANG Zhen(School of Science,Changchun University of Science and Technology,Changchun 130022;School of Life Science and Technology,Changchun University of Science and Technology,Changchun 130022;School of Optoelectronic Engineering,Changchun University of Science and Technology,Changchun 130022;Key Laboratory of Optical Control and Optical Information Transmission Technology,Department of Education,Changchun University of Science and Technology,Changchun 130022)
出处 《长春理工大学学报(自然科学版)》 2018年第6期81-85,共5页 Journal of Changchun University of Science and Technology(Natural Science Edition)
基金 吉林省省级产业创新专项资金项目(2017C046)
关键词 凝血传感器 电磁振动 弹性史撑 模态分析 频谱测试 coagulation sensor electromagnetic vibration spring support modal analysis spectral testing
  • 相关文献

参考文献4

二级参考文献44

  • 1罗阳,张雪,府伟灵.压电石英晶体传感器中的温度效应[J].重庆医学,2004,33(8):1138-1140. 被引量:3
  • 2陆斌,韦钰.基子全内反射萤光原理的免疫传感器[J].中国生物医学工程学报,1993,12(2):142-148. 被引量:26
  • 3Saigo M,Waters DD,Abe S,et al.Soluble fibrin,C-reactive protein,fibrinogen,factor Ⅶ,antithrombin,proteins C and S,tissue factor,d-dimer,and prothrombin fragment 1+2 in men with acute myocardial infarction≤45 years of age[J].Am J Cardiol,2004,94(11):1410-1413.
  • 4Turaj W,Slowik A,Dziedzic T,et al.Increased plasma fibrinogen predicts one-year mortality in patients with acute isehemic stroke[J].J Neurol Sci,2006,246(15):13-19.
  • 5Liu Y,Yin F,Long Y,et al.Study of the immobilization of alcohol dehydrogenase on Au-colloid modified gold electrode by piezoelectric quartz crystal sensor,cyclic voltammetry,and electrochemical impedance techniques[J].J Colloid Interface Sci,2003,258(1):75-81.
  • 6Zhou A,He D,Nie LH,et al.Determination of the binding parameters of drug to protein by equilibrium dialysis/piezoelectric quartz crystal sensor[J].Anal Biochem,2000,282(1):10-15.
  • 7Nomura T,Okuhara M.Frequency shift of piezoelectric quartz crystals immersed in organic liquids[J].Anal Chim Acts,1982,142(2):281-284.
  • 8Kanasawa KK,Gordon JG Ⅱ.The oscillation frequency of a quartz resonator in contact with a liquid[J].Anal Chim Acta,1985,175(9):99-105.
  • 9SHTxx数字温湿度传感器用户手册[EB/OL].Dalian Beifang M & C Ltd.Co.v2.01 March 2003.http://www.dabeco.com.cn
  • 10SHTxx数字温湿度传感器应用程序样例[EB/OL].Dalian Beifang M & C Ltd Co.http://www.dabeco.com.cn.

共引文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部