期刊文献+

捷克共和国的常见接触性致敏物质:疑有接触性皮炎的12058例患者的斑贴试验结果

Common contact sensitizers in the Czech Republic. Patch test results in 12,058 patients with suspected contact dermatitis
下载PDF
导出
摘要 The patch test results of 12 058 patients (4416 male and 7642 female) referred to 9 clinics in the Czech Republic between January 1997 and December 2001 were evaluated. Patients were tested with the same series of allergens by using the standardized patch testing method. The current standard tool for diagnosing allergic contact dermatitis (ACD) in the Czech Republic is the Trolab test panel (Hermal, Reinbeck, Germany) which consists of 23 allergens. Only a few data exists on ACD in the Czech Republic. All patients were tested with the 23 allergen European standard series. Of these patients, 7661 (63.5% ) had 1 or more positive reactions. On average, there were 2.8 positive reactions per patient. ACD, according to clinical relevance, was diagnosed in 5339 (69.7% ) of these patients. The most frequent allergens were metals (22.9% ), especially nickel sulfate (13.8% ), and followed by Myroxylon pereirae resin (balsam of Peru) (7.3% ), fragrance mix (5.8% ), formaldehyde (4.2% ) and lanolin alcohol (3.0% ). Our results were compared with results from other countries. We conclude that the European standard series is suitable for detection of ACD in the Czech Republic. The patch test results of 12 058 patients (4416 male and 7642 female) referred to 9 clinics in the Czech Republic between January 1997 and December 2001 were evaluated. Patients were tested with the same series of allergens by using the standardized patch testing method. The current standard tool for diagnosing allergic contact dermatitis (ACD) in the Czech Republic is the Trolab test panel (Hermal, Reinbeck, Germany) which consists of 23 allergens. Only a few data exists on ACD in the Czech Republic. All patients were tested with the 23 allergen European standard series. Of these patients, 7661 (63.5% ) had 1 or more positive reactions. On average, there were 2.8 positive reactions per patient. ACD, according to clinical relevance, was diagnosed in 5339 (69.7% ) of these patients. The most frequent allergens were metals (22.9% ), especially nickel sulfate (13.8% ), and followed by Myroxylon pereirae resin (balsam of Peru) (7.3% ), fragrance mix (5.8% ), formaldehyde (4.2% ) and lanolin alcohol (3.0% ). Our results were compared with results from other countries. We conclude that the European standard series is suitable for detection of ACD in the Czech Republic.
出处 《世界核心医学期刊文摘(皮肤病学分册)》 2005年第12期56-56,共1页 Digest of the World Core Medical JOurnals:Dermatology
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部