城市户外变电站噪声治理研究 被引量:9

Study on noise control of urban outdoor substation
下载PDF
导出
摘要 介绍了变电站的噪声控制措施,根据噪声超标排放的城市户外变电站布局特点提出了声屏障降噪方案,并设计了对低频噪声具有良好吸声作用的声屏障用吸隔声模块。经声学仿真和现场安装测试,声屏障降噪效果明显,站界噪声排放和敏感点处的声环境均能满足相关标准要求。该案例的成功实施为今后城市变电的噪声防治提供了借鉴和参考。 The noise control methods of substation are introduced.According to the layout characteristics of urban outdoor substation with excessive noise emission,the sound barrier scheme is proposed,and the barrier modules with sound absorption function is designed for low frequency noise.By acoustic simulation and field installation test,the sound barrier has obvious noise reduction effect,the acoustic environment of the substation boundary and sensitive point can meet the relevant standard requirements.The successful implementation of this case can provide reference for the noise prevention and control of urban substation.
作者 孟晓明 陈胜男 杨黎波 王利民 裴春明 MENG Xiaoming;CHEN Shengnan;YANG Libo
出处 《电力科技与环保》 2019年第3期1-3,共3页 Electric Power Technology and Environmental Protection
基金 国家电网公司科技项目(SGTYHT/16-JS-198)
关键词 变电站 变压器 降噪 声屏障 吸声材料 substation transformer reducing noise sound barrier sound absorption material